background image

FCC Notice

This equipment has been tested and found to comply with the limits for 
a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful in-
terference in residential installation. This equipment generates, uses, and 
can radiate radio frequency energy and, if not installed and used in ac-
cordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not 
occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful 
interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct 
the interference by one or more of the following measures: 

(1) 

Reorient or relocate the receiving antenna. 

(2) 

Increase the separation between the equipment and receiver. 

(3) 

Connect the equipment into an outlet on a circuit different from that to 

which the receiver is connected. 

(4) 

Consult the dealer or an experienced radio/TV technician for help. Any 

special accessories needed for compliance must be specified in the in-
struction. 
 

If you require technical support or equipment service, please contact 
the  Panamax  Service  Department  at  800-472-5555.  You  may  also 
email [email protected].
 
All equipment being returned for repair must have a Return Authori-
zation  (RA)  number. To  get  an  RA  number,  please  call  the  Panamax 
Service Department. 

Before returning any equipment for repair, please be sure that it is ad-
equately packed and cushioned against damage in shipment, and that 
it is insured. We suggest that you save the original packaging and use it 
to ship the product for servicing. Also, please enclose a note giving your 
name, address, phone number and a description of the problem. 

Contacting Customer Service

® 2010 Panamax LLC,  1690 Corporate Circle, Petaluma, CA 94954    •   www.panamax.com   •   707-283-5900   •  Fax 707-283-5901 

INS00860 REV. D      5/17/10 

12

M4320-PRO Specifications

AC Power

________________________________________________

Line Voltage................................................................................120V, 60Hz
Isolated Banks...........................................................................................4
Voltage Regulation...................................................................................No
Total Outlets...................................................................................9 Outlets
High Current Outlets.......................................................................2 Outlets
Total Current Capacity...........................................M4320-PRO 20 A (2400W)
Voltage Protection Rating (UL 1449 3rd Edition, 3,000A):......................330V
Protection Modes....................................................................L-N, L-G, N-G
Initial Clamping Level.................................................200V Peak, 141V RMS
Energy Dissipation.................................................................... 2700 Joules
Peak Impulse Current............................................................135,000 Amps
Catastrophic Surge Circuit.......................................................................Yes
Thermal Fusing:.....................................................................................Yes

Auto-resetting Over-voltage shutoff....................................134 VAC ± 2 VAC
Auto-resetting Under-voltage shutoff..................................100 VAC ± 2 VAC

LAN Protection

____________________________________________

Clamping Level................................................................................62 ± 6V
Compatibility................................................................10/100/1000BASE-T
Jacks..................................................................................................RJ-45
Wires Protected:...............................................................................8-Wires

Telco Protection

___________________________________________

Fuseless/Auto-resetting..........................................................................Yes
Clamping Level....................................................................................260V
Capacitance...........................................................................30pf (approx.)
Suppression Modes...................................................Metallic & Longitudinal
Connectors.........................................................................................RJ-11
Lines Protected................................................................2-Wire, Pins 4 & 5

Universal Coax Protection

___________________________________

HD 1080 i/p Ready..................................................................................Yes
Bidirectional............................................................................................Yes
Shielded..................................................................................................Yes
Clamping Level......................................................................................75V
Frequency Range....................................................................0Hz - 2.2 GHz
Insertion Loss.................................................................................< 0.5 dB
Connectors..............................................................Female “F”, Gold Plated

Specifications subject to change due to product upgrades and improvements.

CAUTION: 

A shielded-type power cord is required in order to meet FCC 

emission limits and also to prevent interference to the nearby radio and 
television  reception.  It  is  essential  that  only  the  supplied  power  cord 
be used. Use only shielded cables to connect RS-232 devices to this 
equipment. 

CAUTION:

 

Any changes or modifications not expressly approved by the 

guarantee of this device could void the user’s authority to operate the 
equipment. 

12v trigger input 5-24 volts DC , 820 ohms Jacks 3.5mm (1/8”) mono 
mini-plug.

Содержание M4320-PRO

Страница 1: ...kHz 46 db 250 kHz 1 MHz One Isolated Filter Bank for High Current Devices 60db 5 kHz 450 kHz 46 db 450 kHz 1 MHz Front Panel Circuit Breaker Integrated Front Rack Ears 12 Volt Input Triggering Detacha...

Страница 2: ...RIGHTNESS OUTLET STATUS REBOOT 1 REBOOT 2 M4320 PRO B LT Blue ENABLED VOLTS RS232 Table of Contents Feature Descriptions pg 1 Important Safety Instructions Front Panel Features Overview pg 2 Preset Pr...

Страница 3: ...time This can cause speaker thumps which are not only annoy ing but can also damage the speakers and or trip product circuit breakers The M4320 PRO is designed to eliminate these transients by provid...

Страница 4: ...te a full power up or shut down sequence The front panel outlet is always on unless the circuit breaker is set to OFF VOLTS AMPS BRIGHTNESS Ro tate knob for front panel brightness control and press to...

Страница 5: ...off BREAKER or holding both REBOOT buttons A V EXTENDED DELAYS OUTLET SEQUENCING profile P3 by outlet s Start up 1 10 sec 2 10 sec 3 10 sec 4 10 sec 5 10 sec 6 10 sec 7 20 sec 8 Shut down 8 20 sec 7 2...

Страница 6: ...75V clamping HD 1080i p ready 0 5 dB 0 Hz 2 2 GHz 5 LAN Cat 5e 10 100 1000BASE T compatible RJ 45 8P8C Ethernet protection pass through 6 Telco RJ 11 6P2C analog telephone DSL protection pass through...

Страница 7: ...e or telephone DSL line from the M4320 PRO back to modem router s input Step 4 Plug in and switch on M4320 PRO SYSTEM SETUP 2 Network Equipment NOT Powered by M4320 PRO devices in separate rooms Step...

Страница 8: ...________________________________________ __________________________________________ __________________________________________ __________________________________________ ______________________________...

Страница 9: ...s list before proceeding The BlueBOLT CV1 should already be factory installed in this Panamax M4320 PRO component To switch from BlueBOLT functionality to RS 232 connectivity follow these steps 1 Unpl...

Страница 10: ...4 ALL ON Turns on all outlets Turn on is immediate with no delay 3 4 1 Command ALL_ON CR 3 4 2 Action All outlet relays turn ON Terminates any running turn on or turn off sequence Overrides the DC tri...

Страница 11: ...FOR 6 20 11 DELAY FOR 7 21 6 DELAY FOR 8 26 1 3 7 SET REBOOT DELAY Assign the delay between the last outlet turning off and the beginning of the turn on se quence in a reboot cycle 3 7 1 Command SET_R...

Страница 12: ...e PROFILE n SELECTED CR 4 QUERIES 4 0 IDENTIFY Request that the unit identify itself 4 0 1 Query ID CR 4 0 2 Response PANAMAX CR MAX 4315 PRO CR FIRMWARE revision CR 4 1 FAULT STATUS Request the on of...

Страница 13: ...R status CR 5 7 3 Condition When a wire fault is detected a message will be sent to indicate the status of the indicator 5 7 4 Message WIRE FAULT status CR 5 7 5 Condition When the temperature exceeds...

Страница 14: ...number and a description of the problem Contacting Customer Service 2010 Panamax LLC 1690 Corporate Circle Petaluma CA 94954 www panamax com 707 283 5900 Fax 707 283 5901 INS00860 REV D 5 17 10 12 M43...

Отзывы: