FCC Notice
This equipment has been tested and found to comply with the limits for
a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful in-
terference in residential installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in ac-
cordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
(1)
Reorient or relocate the receiving antenna.
(2)
Increase the separation between the equipment and receiver.
(3)
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
(4)
Consult the dealer or an experienced radio/TV technician for help. Any
special accessories needed for compliance must be specified in the in-
struction.
If you require technical support or equipment service, please contact
the Panamax Service Department at 800-472-5555. You may also
email [email protected].
All equipment being returned for repair must have a Return Authori-
zation (RA) number. To get an RA number, please call the Panamax
Service Department.
Before returning any equipment for repair, please be sure that it is ad-
equately packed and cushioned against damage in shipment, and that
it is insured. We suggest that you save the original packaging and use it
to ship the product for servicing. Also, please enclose a note giving your
name, address, phone number and a description of the problem.
Contacting Customer Service
® 2010 Panamax LLC, 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com • 707-283-5900 • Fax 707-283-5901
INS00860 REV. D 5/17/10
12
M4320-PRO Specifications
AC Power
________________________________________________
Line Voltage................................................................................120V, 60Hz
Isolated Banks...........................................................................................4
Voltage Regulation...................................................................................No
Total Outlets...................................................................................9 Outlets
High Current Outlets.......................................................................2 Outlets
Total Current Capacity...........................................M4320-PRO 20 A (2400W)
Voltage Protection Rating (UL 1449 3rd Edition, 3,000A):......................330V
Protection Modes....................................................................L-N, L-G, N-G
Initial Clamping Level.................................................200V Peak, 141V RMS
Energy Dissipation.................................................................... 2700 Joules
Peak Impulse Current............................................................135,000 Amps
Catastrophic Surge Circuit.......................................................................Yes
Thermal Fusing:.....................................................................................Yes
Auto-resetting Over-voltage shutoff....................................134 VAC ± 2 VAC
Auto-resetting Under-voltage shutoff..................................100 VAC ± 2 VAC
LAN Protection
____________________________________________
Clamping Level................................................................................62 ± 6V
Compatibility................................................................10/100/1000BASE-T
Jacks..................................................................................................RJ-45
Wires Protected:...............................................................................8-Wires
Telco Protection
___________________________________________
Fuseless/Auto-resetting..........................................................................Yes
Clamping Level....................................................................................260V
Capacitance...........................................................................30pf (approx.)
Suppression Modes...................................................Metallic & Longitudinal
Connectors.........................................................................................RJ-11
Lines Protected................................................................2-Wire, Pins 4 & 5
Universal Coax Protection
___________________________________
HD 1080 i/p Ready..................................................................................Yes
Bidirectional............................................................................................Yes
Shielded..................................................................................................Yes
Clamping Level......................................................................................75V
Frequency Range....................................................................0Hz - 2.2 GHz
Insertion Loss.................................................................................< 0.5 dB
Connectors..............................................................Female “F”, Gold Plated
Specifications subject to change due to product upgrades and improvements.
CAUTION:
A shielded-type power cord is required in order to meet FCC
emission limits and also to prevent interference to the nearby radio and
television reception. It is essential that only the supplied power cord
be used. Use only shielded cables to connect RS-232 devices to this
equipment.
CAUTION:
Any changes or modifications not expressly approved by the
guarantee of this device could void the user’s authority to operate the
equipment.
12v trigger input 5-24 volts DC , 820 ohms Jacks 3.5mm (1/8”) mono
mini-plug.