background image

1.  Power inlet:

 M4315-PRO (120 Vac/15 A, IEC 320 C14) do not remove steel retention 

clip.   M4320-PRO (120 Vac/20 A, IEC 320 C20) do not remove steel retention clip. 

2. Ground lug: 

connect to Panamax MOD-series signal protection module grounding busses 

with 14 AWG (<12” length) wire to expand signal protection capabilities

3. Outlets:

 all rear panel outlets are separately controlled. They are grouped into four (4) 

filter-isolated banks.

   

3-A  

BANKS 1-3: filtered outlet s (>76 dB @ 5 KHz – 150 KHz, 

                            

        >46 dB @ 150 KHz – 5 MHz)

   

3-B 

BANK 4: high-current outlets (>59 dB, 5 KHz – 450 KHz, 

                                     >46 dB @ 450 KHz – 5 MHz)

4. CATV/SAT 1 & 2: 

Universal voltage (±75V clamping), HD 1080i/p ready, <0.5 dB @ 

0 Hz - 2.2 GHz. 

5. LAN Cat 5e 

(10/100/1000BASE-T compatible): RJ-45 (8P8C) Ethernet protection 

pass-through.

6. Telco: 

RJ-11 (6P2C) analog telephone/DSL protection pass-through. 

Do not connect in reverse (IN comes in from wall, OUT connects to equipment).

7. DC Trigger Input:

 3.5mm mono jack, ± (5-24 VDC) tip-ring.

8. TCP/IP card (BlueBOLT)

 installed

9. Communications card: 

RS-232 (female DE-9) 

included, not installed. 

GROUND

OUTLET 8                 OUTLET 7                   OUTLET 6                    OUTLET 5                  OUTLET 4                  OUTLET 3                   OUTLET 2                  OUTLET 1

FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC 

TRIGGER

AC INLET

FILTER BANK 4 - HIGH CURRENT                 

IN

O

U

T

1.

2.

3.

4.

5.

6.

8.

OUTLET 8                  OUTLET 7                        

FILTER BANK 4                                            

3-A 

3-A 

3-A 

3-B 

7.

BlueBOLT-CV1

M4320-PRO

BlueBOLT™ (Installed)

RS-232 INSTALLATION (optional)

It is recommended that you read the entire instructions list before proceeding. 

The BlueBOLTCV-1 should already be factory installed in this Panamax Pro component.  

To switch from BlueBOLT functionality to RS-232 connectivity, follow these steps:

CAUTION! WARRANTY LIMITATION FOR INTERNET PURCHASERS

Panamax  products  purchased  through  the  Internet  do  not  carry  a  valid  Product  Warranty  or 

Connected Equipment Protection Policy unless purchased from an Authorized Panamax Internet 

Dealer and the original factory serial numbers are intact (they must not have been removed, defaced 

or replaced in any way). Purchasing from an Authorized Panamax Internet Dealer insures that the 

product was intended for consumer use, has passed all quality inspections and is safe. Buying 

through auction sites or unauthorized dealers may result in the purchase of salvaged, failed and/or 

products not intended for use in the US. In addition, Authorized Panamax Internet dealers have 

demonstrated sufficient expertise to insure warranty compliant installations.

For a list of Authorized Panamax Internet Dealers go to www.panamax.com

Panamax Limited Product Warranty* 

Panamax Inc. warrants to the purchaser of this product for a period of three (3) years from the date of 

purchase, that the unit shall be free of defects in design, material or workmanship, and Panamax Inc. will 

repair or replace any defective unit.

QSG00859 REV. G    ENG

2.

REAR PANEL FEATURE OVERVIEW

*Full Warranty and policy Information available at www.panamax.com

$5,000,000 Connected Equipment Limited Protection Policy* 

All Panamax Warranties and Connected Equipment Policies are valid only in the United States & Canada.

This equipment (BlueBOLT™ IP Card) has been tested and found to comply with the limits for a Class B digital device, pursuant 

to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that 

interference will not occur in a particular installation.

FCC CLASS B DIGITAL DEVICE INFORMATION

www.panamax.com

Advanced Operation

Besides providing access to Panamax/Furman’s hosted BlueBOLT platform, the included 
BlueBOLT-CV1 card also supports the following networking protocols:
 

 

• Telnet (default port 23), for interfacing to control and 

 

    automation systems within the local network.

 

• HTTP (web server at default port 80) for configuring the 

 

   network settings for stand-alone “static IP” operation.

For more information, see the application note BlueBOLT Advanced Networking, available 
online 

at www.mybluebolt.com.

RS232

9.

STEP 1.

 Connect an Ethernet cable (sold 

separately) between the BlueBOLT-CV1 card 

and an Internet router or modem with an 

established Internet connection.

STEP 2.

 On-Line Registration (Step 2 of 2) 

Your BlueBOLT™ enabled Power 

Management Component is completely 

plug-and-play and does not require any 

software installation. The online BlueBOLT™ 

control interface is operated through your 

web browser. 

a)

 Using any Internet connected computer 

go to  www.mybluebolt.com using your 

standard Internet browser.

b)

 Follow the on screen prompts, add a 

location, and then add a device. 

 Note:

 you 

will need the BlueBOLT-CV1’s unique MAC 

address and challenge key (provided on the 

card’s protective packaging as well as on the 

label of the card itself) in order to register 

the unit online.

c)

 Once you input the MAC address and 

included challenge key, if BlueBOLT™ 

cannot detect your device (please allow up 

 to 20 seconds), please follow the on-

screen troubleshooting guide. Also confirm 

the Power Management Component is 

properly connected to the Internet.

• Is your Power Management Component 

receiving power? Check the power cable 

and confirm the unit is on.

• Is your BlueBO

LT-CV1 card installed 

properly? The “Link” light should be 

illuminated (solid green) and the “Activity” 

light should be blinking intermittently 

(green).

• Is your Internet connection functioning? 

Can you access a general web page?

• Is your BlueBO

LT-CV1 card connected to 

your internet router or modem? Check the 

Ethernet cable and confirm that the unit is 

connected to an active Internet connection, 

and make sure those connected devices are 

receiving power.

• If you have answered “

Yes” to all of these 

questions and are still unable to connect 

your Power Management component, 

please contact Panamax customer service 

at 1-800-472-5555.

STEP 

1.

 Unplug M4315-PRO or 

M4320-PRO Power Management 

Component from wall.

STEP 

2.

 Unplug Ethernet cable from 

BlueBOLT-CV1 card.

STEP 

3.

 Remove the BlueBOLT-CV-1 

card using thumbscrews. Note minimal 

torque should be applied in removal of 

the existing card. 

STEP 4. 

 Remove RS-232 card from 

protective packaging.

STEP 

5.

 Noting the 2 guiding channels 

within the card slot, gently slide the 

RS-232 card into the card slot, making 

sure to screw the thumbscrews down for 

a snug and secure fit.

STEP 6

.

 Connect RS-232 cable  (sold 

separately) to the RS-232 card to 

establish to a connection between the 

Power Management  component and an 

RS-232 enabled Home Theater control 

device.

STEP 7

.

 Plug in Power Management 

Component to an AC power receptacle.

Содержание M4315-PRO

Страница 1: ...OUTLET 5 OUTLET 4 OUTLET 3 OUTLET 2 OUTLET 1 FILTER BANK 4 FILTER BANK 3 FILTER BANK 2 FILTER BANK 1 CATV SAT 1 CATV SAT 2 LAN CAT 5e TELCO DC TRIGGER AC INLET BlueBOLT CV1 IN O U T GROUND OUTLET 8 O...

Страница 2: ...RING FAULT TEMPERATURE 15 A OUTLET STATUS REBOOT 1 REBOOT 2 M4315 PRO B LT Blue VOLTS ALWAYS ON VOLTS AMPS BRIGHTNESS M4320 PRO 20 Amp 1 DEFAULT OUTLET SEQUENCING preset profile P1 by outlet s With sw...

Страница 3: ...ovide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance...

Страница 4: ...OUTLET STATUS REBOOT 1 REBOOT 2 M4315 PRO B LT Blue COMPATIBLE VOLTS ALWAYS ON VOLTS AMPS BRIGHTNESS M4320 PRO 20 Amp SECUENCIA PREDETERMINADA DEL TOMACORRIENTE perfil preajustado P1 por s de tomacor...

Страница 5: ...s Panamax y conectado Pol ticas de equipo son s lo v lidos en los Estados Unidos y Canad Garant a completa est disponible en www panamax com BlueBOLT Instalado Operaci n avanzada Adem s de proporciona...

Страница 6: ...OOT 2 M4315 PRO B LT Blue COMPATIBLE VOLTS ALWAYS ON VOLTS AMPS BRIGHTNESS M4320 PRO 20 Amp S QUENCE DES PRISES PAR D FAUT profil pr configur P1 par num ros de prise Avec la mise sous tension et hors...

Страница 7: ...BLOCS 1 3 prises filtr es 76 dB 5 KHz 150 KHz 46 dB 150 KHz 5 MHz 3 B BLOC 4 prises haute tension 59 dB 5 KHz 450 KHz 46 dB 450 KHz 5 MHz 4 CATV SAT 1 2 Universal voltage 75V clamping HD 1080i p read...

Страница 8: ...T 8 OUTLET 7 OUTLET 6 OUTLET 5 OUTLET 4 OUTLET 3 OUTLET 2 OUTLET 1 FILTER BANK 4 FILTER BANK 3 FILTER BANK 2 FILTER BANK 1 CATV SAT 1 CATV SAT 2 LAN CAT 5e TELCO DC TRIGGER AC INLET BlueBOLT CV1 IN O...

Отзывы: