The Bubble of Protection

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

Rear Panel Features Overview

1.  Power inlet:

 M4315-PRO (120 Vac/15 A, IEC 320 C14) do not remove 

steel retention clip.  

2.  Ground  lug:

  connect  to  Panamax  MOD-series  signal  protection  module 

grounding busses with 14 AWG (<12” length) wire to expand signal protection 
capabilities.

3. Outlets:

 all rear panel outlets are separately controlled. They are grouped 

into four (4) filter-isolated banks.

 

BANKS 1-3:

  

Filtered Outlets (Outlets 1, 2, 3, 4, 5, 6)

 

 

76dB (5 kHz – 250 kHz),  46dB (250 kHz - 1 MHz)

                            

                         

        _____________________________________________
       

BANK 4: 

High-Current Outlets 

(Outlets 7-8)

       

60dB (5 kHz – 450 kHz),  46dB (450 kHz - 1 MHz)

4. CATV/SAT 1 & 2:

 Universal voltage (±75V clamping), HD 1080i/p ready, 

<0.5 dB @ 0 Hz - 2.2 GHz. 

5. LAN Cat 5e 

(10/100/1000BASE-T compatible): RJ-45 (8P8C) Ethernet 

protection pass-through.

6. Telco:

 RJ-11 (6P2C) analog 

telephone/DSL protection pass-
through. Do not connect in reverse 

OUT 

Connects to Equipment

IN

 - 

Comes in from the wall

7. DC Trigger Input: 

3.5mm mono jack, ± (5-24 VDC) tip ring.

 

8. TCP/IP card (BlueBOLT) installed

9. Communications Card: RS-232 

(female DB-9) included, not shown.

1.

2.

4.

5.

8.

7.

6.

4

Sample setup to indicate the basic configuration for a “Bubble of Protection”.

9.

OUT          IN

BANK 4                   BANK 3                   BANK 2                  BANK 1     

GROUND

OUTLET 8                  OUTLET 7                  OUTLET 6                  OUTLET 5                    OUTLET 4                  OUTLET 3                   OUTLET 2                   OUTLET 1

FILTER BANK 4                                             FILTER BANK 3                                             FILTER BANK 2                                              FILTER BANK 1

CATV / SAT 1        CATV / SAT 2

LAN CAT 5e

TELCO

DC TRIGGER

AC INLET

BlueBOLT-CV1

IN

O

U

T

M4315-PRO

TV

BUBBLE O

F PR

OTE

CTIO

N

NETWORK SWITCH

SAT

SAT

CAT 5e

DVD / BLU-RAY

A / V RECEIVER

MEDIA SERVER / EXTENDER

DVR

SUB

MIW-XT OUTLET

MIW-XT INLET

AC
COAX
CAT 5e
SIGNAL
SPEAKER

Содержание M4315-PRO

Страница 1: ...B LT Blue ENABLED VOLTS Power Management with Control System Interactive Functionality 15 Amp Capacity M4315 PRO 8 Individually Controllable Rear Panel Outlets Fully Programmable TCP IP BlueBOLT Insta...

Страница 2: ...BRIGHTNESS OUTLET STATUS REBOOT 1 REBOOT 2 M4315 PRO B LT Blue ENABLED VOLTS RS232 Table of Contents Feature Descriptions pg 1 Important Safety Instructions Front Panel Features Overview pg 2 Preset P...

Страница 3: ...time This can cause speaker thumps which are not only annoy ing but can also damage the speakers and or trip product circuit breakers The M4315 PRO is designed to eliminate these transients by providi...

Страница 4: ...connection Front Panel Features Overview PULL OUT CARD Quick reference for default profile and device type list Located under the reboot buttons REBOOT 1 2 Press either button for 2 seconds to initiat...

Страница 5: ...d off BREAKER or holding both REBOOT buttons A V EXTENDED DELAYS OUTLET SEQUENCING profile P3 by outlet s Start up 1 10 sec 2 10 sec 3 10 sec 4 10 sec 5 10 sec 6 10 sec 7 20 sec 8 Shut down 8 20 sec 7...

Страница 6: ...______________________ BANK 4 High Current Outlets Outlets 7 8 60dB 5 kHz 450 kHz 46dB 450 kHz 1 MHz 4 CATV SAT 1 2 Universal voltage 75V clamping HD 1080i p ready 0 5 dB 0 Hz 2 2 GHz 5 LAN Cat 5e 10...

Страница 7: ...e room Step 1 Connect the power supply for the modem router into the M4315 PRO Step 2 Connect the coaxial line or telephone DSL line from the wall to M4315 PRO signal line pass through protection circ...

Страница 8: ...________________________________________ __________________________________________ __________________________________________ __________________________________________ ______________________________...

Страница 9: ...s list before proceeding The BlueBOLT CV1 should already be factory installed in this Panamax M4315 PRO component To switch from BlueBOLT functionality to RS 232 connectivity follow these steps 1 Unpl...

Страница 10: ...4 ALL ON Turns on all outlets Turn on is immediate with no delay 3 4 1 Command ALL_ON CR 3 4 2 Action All outlet relays turn ON Terminates any running turn on or turn off sequence Overrides the DC tri...

Страница 11: ...FOR 6 20 11 DELAY FOR 7 21 6 DELAY FOR 8 26 1 3 7 SET REBOOT DELAY Assign the delay between the last outlet turning off and the beginning of the turn on se quence in a reboot cycle 3 7 1 Command SET_R...

Страница 12: ...e PROFILE n SELECTED CR 4 QUERIES 4 0 IDENTIFY Request that the unit identify itself 4 0 1 Query ID CR 4 0 2 Response PANAMAX CR MAX 4315 PRO CR FIRMWARE revision CR 4 1 FAULT STATUS Request the on of...

Страница 13: ...REAKER status CR 5 7 3 Condition When a wire fault is detected a message will be sent to indicate the status of the indicator 5 7 4 Message WIRE FAULT status CR 5 7 5 Condition When the temperature ex...

Страница 14: ...number and a description of the problem Contacting Customer Service 2010 Panamax LLC 1690 Corporate Circle Petaluma CA 94954 www panamax com 707 283 5900 Fax 707 283 5901 INS00859 REV D 5 11 10 12 M43...

Отзывы: