© Pan Acoustics GmbH
V 1.0
Page 4 of 7
Assembly Manual
Rigid Wall Mount
4. Assembly and use instructions
4.1. Overview of assemblies
Description
Drawing
Slot nut 30 x 5 x 90 mm
A
Set screw, M6 x 8 washer, A2, DIN 916
B
Bracket (speaker)
C
Cylinder screw M6 x 10, A2, DIN 7984
D
Bracket (wall)
E
Hex nut, M6, A2, DIN 985, self-locking
F
Washer, M6, A2, DIN 9021
G
Washer, A 8.4, polyamide, black, DIN 125
H
Cup square bolt, M6 x 45, A2, DIN 603
I
B
•
The speaker accessory is not to be used for lifting, lowering or securing people or objects other
than the specifi ed speakers from the Pan Beam and Pan Speaker series.
•
The Rigid Wall Mount is rated for the assembly of speaker systems weighing up to 11 kg.
•
It is recommended to use an additional securing element to secure each suspended speaker
against falling.
•
In general, a visual inspection of the speaker and the accessory is to be performed prior to
each use/assembly. If there are signs of wear, cracking or deformation, they are to be replaced
without delay. The visual inspection also includes checking the screw connections on load-
bearing parts of the speaker and accessory.
A
C
D
I
G
H
F
E
Model
P 02-Pi
P 04
PB 04
P 08-Pi
PB 08
P 16-Pi
PB 16
PB 24
PB 32
PB 40
Brackets
1
1
1
2
2
4
5
Number of brackets depending upon speaker module