Page 11
REQUIRED CONNECTIONS
Required connections are: RF IN, RF OUT and PTT.
The phono input PTT can be activated by any transceiver with a PTT
cable from the LA-1K to the transceiver (not supplied)
. When PTT is
grounded
TX
is displayed and the LA-1K is ready to transmit.
Rear Panel
RF Deck
Front Panel
AC Input Filter
+/- 12V (bias)
Dual Output
Filters
+50V @ 42A
Power Supply
PALSTAR
Page 12
EXTERNAL DATA CONNECTORS
Table of YAESU/ELECRAFT
Band Selections and
4 Bit BCD Codes
Table of ICOM
Bands and Voltage
Level (Pin 5)
0 = low voltage (0 V)
1 = high voltage (5 V)
Band
DBCA
60m
0000
160m
0001
80m
0010
40m
0011
30m
0100
20m
0101
17m
0110
15m
0111
12m
1000
10m
1001
6m
1010
NC
1111
NC
0 V
160m
7.5 V
80m
6.5 V
40m
5.5 V
30m
0.5 V
20m
4.5 V
17/15m
3.5 V
12/10m
2.5 V
6m
1.5 V
MARS Frequency
Usage
Range
2.011-25.401 MHz
Power Level
400 W
Emissions
3K00J3E/J2D
NOTE:
30M is NOT a separate band on the
LA-1K. When the band voltage drops to
zero, the LA-1K correctly switches to 20M.
This allows operation on the 30M band but
without “
DIRECT KEYING
” due to cable
detection by checking for voltage on ICOM
band data input. 30M is limited to 200W
and ampli er operation is not normally
required on this band.