Page 9

ALC ADJUSTMENT PROCEDURE

NOTE:  Ampli  er ALC is only used for SSB voice transmission.

• 

Connect the ALC cable from transceiver to the LA-1K ampli  er

• 

Set the ALC BASE VALUE to minimum on the LA-1K as described on 

the previous page

• 

Place the transceiver in CW or RTTY (NOT AM or FM)

• 

With the LA-1K in standby mode set the transceiver to an initial 

power level of about 30 Watts then unkey the transmitter

• 

Switch the LA-1K to OPERATE MODE (OPR) by pressing MODE

• 

Transmit and adjust transmitter output to achieve the desired output 

power level.  Do not exceed 1000 Watts output or 60 Watts drive 

power (to avoid splatter).  

UNKEY TRANSMITTER

• 

Switch transceiver to LSB or USB transmission.  Press MENU on the 

LA-1K and NEXT until the SELECT ALC BASE VALUE screen is visible.  

Transmit speaking in the microphone and adjust the LA-1K ALC base 

value increasing the ALC voltage until the power output starts to 

drop.  The point where power drops slightly is the correct setting.  

Push EXIT to return to the main screen on the LA-1K

NOTE: 

More precise adjustments may be made by connecting an 

oscilloscope to observe the output for clipping.

PALSTAR

Page 14

HOW TO UPDATE FIRMWARE

DOWNLOADING and INSTALLING  LA-1K FIRMWARE

• 

DOWNLOAD the latest Firmware   le (a ZIP archive) from the Palstar 

website

http://www.palstar.com/en/la-1k/

. The download link is near 

the bottom of the page. The link to the   le is named “LATEST FIRMWARE 

LINK: LA-1K FIRMWARE x.x.ZIP” where x.x is the latest revision number.

• 

SAVE

 the ZIP   le to a location on your computer

• 

OPEN

 the folder by right-clicking on the ZIP   le and select “Extract All” - 

follow the steps in the Extraction Wizard.  After extracting, a FOLDER will 

be created called “la-1k_  rmware_XX” where XX is the revision number.

• 

CONNECT

 one end of the USB cable to a USB port on your computer.

• 

DOUBLE-CLICK 

 “LOAD_LA-1K.exe” within the folder containing the 

 rmware download.

• 

Follow the instructions on the opened computer window and use the 

“Browse” button to select the   rmware version to be loaded.

• 

Press and 

HOLD

 the GREY button to the right of the USB port labeled 

PROGRAM UPDATES

” during the next two steps.

• 

CONNECT

 the other end of the USB cable to the LA-1K front panel. A 

“Found 1 Device” message will appear on the right side of the opened 

computer window.

• 

TURN ON

 the LA-1K.

• 

RELEASE

 the GREY button on the LA-1K front panel.

• 

CLICK

 on the “Update Firmware” button that is on the opened computer 

window. Wait until the green bar in the middle of the computer window 

shows that the programming completes by scrolling from left to right. 

The   rmware version number on the LA-1K is on the bottom line of the 

start up screen.

Содержание LA-1K

Страница 1: ...ons Summary 1000 Watts PEP CW ICAS 160m to 6m RF Sensing Auto Band Switching Color TFT Touch Screen Variable Speed Fans 12 75 x 6 25 x 16 5 Weight 27 lbs 12 3 kg 9676 N Looney Road Piqua OH 45356 USA...

Страница 2: ...1K should always be in BYPASS for antenna tuner adjustments SWR HIGH TX WAIT displays The ampli er will not key up until the SWR indication is below 2 5 1 It is waiting for lower SWR before keying up...

Страница 3: ...o meet and exceed FCC requirements on all U S amateur radio frequencies where ampliers are allowed If this amplier is used on non amateur frequencies please note that specications are not guaranteed o...

Страница 4: ...Tuner After the HF AUTO is tuned push MODE to select OPR for operation mode PALSTAR Page 20 NORMAL MODE KEYING HOW KEYING WORKS When the PTT line goes low the ampli er won t close it s transmitting ou...

Страница 5: ...To switch into operational mode or OPR press the MODE button on the touch screen display until OPR mode operational is displayed The red power bar indicator will only be visible when transmitting OPE...

Страница 6: ...isplay This message appears on the display when the PTT line is grounded but no RF is present RF must be applied with PTT line low to key the ampli er to the transmit state Won t amplify or auto band...

Страница 7: ...ss Vd as seen on the TFT display The LA 1K is in BYPASS to protect from loss of 50V drain voltage supply The fault should clear in a few seconds This can occur when operating on 120V if the drain curr...

Страница 8: ...WR This indication appears when the SWR is or has been over 2 5 1 during a transmission Transient faults such as antenna arcing can show a low SWR after the fault event while the transmitter is still...

Страница 9: ...grade power supply of the LA 1K was designed to behave this way and will not be damaged When using the LA 1K with a 208 250 VAC supply operation at 1000W PEP is available on all bands It is recommend...

Страница 10: ...OWNLOAD the latest Firmware le a ZIP archive from the Palstar website http www palstar com en la 1k The download link is near the bottom of the page The link to the le is named LATEST FIRMWARE LINK LA...

Страница 11: ...CD B IN 2 BCD A IN 3 Kenwood RX data IN 4 Kenwood TX data OUT 5 ICOM Band Data 6 GROUND 7 Amp Key IN 8 BCD D IN 9 BCD C IN PIN FUNCTION 1 N C 2 RS 232 Transmit 3 RS 232 Receive 4 N C 5 GROUND 6 N C 7...

Страница 12: ...Voltage Level Pin 5 0 low voltage 0 V 1 high voltage 5 V Band DBCA 60m 0000 160m 0001 80m 0010 40m 0011 30m 0100 20m 0101 17m 0110 15m 0111 12m 1000 10m 1001 6m 1010 NC 1111 NC 0 V 160m 7 5 V 80m 6 5...

Отзывы: