background image

 

 
 
 

 
 
If a gas leak is detected: 

 

Do not turn power switches on or off. 

 

Do not plug or unplug electrical appliances.  

 

Do not use the telephone. 

 
Flame or sparks may ignite the gas and cause a fire: 

 

Cease operation immediately and close the gas valve. 

 

Open windows and doors for ventilation. 

 

Contact your gas supplier, a licensed plumber or Rheem Service on 131 031. 

 
 
 
 

 
 
 

 

DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLAINCE. 

 

DO NOT SPRAY AEROSALS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION. 

 

DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE. 

 

DO NOT MODIFY THIS APLLIANCE. 

 

THIS HEATER IS NOT INTENDED FOR USE AS A FIREPLACE INSERT. 

 

NOT TO BE CONNECTED TO AN LPG GAS CYLINDER LOCATED INDOORS. 

 

For information on the gas consumption and gas type please see data plate. 

 

Please ensure that the gas specified on the rating plate matches your gas supply. Using a different type 
of gas may cause an explosive ignition resulting in injury, damage to heater or malfunction of the oxygen 
depletion  safety  system.  Do  not  install  heater  if  it  is  the  wrong  gas  type.  Please  contact  your  place  of 
purchase immediately. 

 

Electrical supply must be 240v, 50 Hz. 

 

Use only the gas hose supplied with the heater to avoid risk of gas leakage. 

 

Ventilation and room sizing must comply with local regulations. This heater is not intended for a fireplace 
insert. 

 

Ensure  your  room  is  correctly  ventilated  while  unit  is  operating. Continuous  use  decreases  the  oxygen 
level in the room which activates the oxygen depletion safety system. 

 

Do not allow curtains or other flammable materials or aerosol cans to come into contact with the heater. 
It may cause a fire or the pressure in the aerosol-can may increase resulting in an explosion. 

 

Do  not  use  or  store  gasoline,  benzene,  aerosol  or  any  other  flammable  material  near  this  appliance. It 
may result in a fire. 

 

Do not post or allow children to post articles such as paper, cloth or any  other foreign material into the 
louvres or air inlet of the heater. Do not block the louvres or the air inlet of the heater. This may cause a 
fire or overheat the appliance. 

 

Do not leave the heater unattended or alight when you leave the house. 

 

Do not sit, stand or sleep directly in front of the heater. Receiving direct heat continuously may cause low 
temperature burns. The aged, children, a very tired person, a person with sensitive skin or an intoxicated 
person must be supervised at all times. 

 

If  your  heater  fails  to  operate  correctly  or  you  detect  any  unusual  odours  during  its  operation,  cease 
operation immediately and close the gas valve. Refer to the trouble shooting section of these instructions 
and if the problem cannot be fixed please contact your gas supplier or Rheem service. 

 

This  heater  must  be  repaired  or  serviced  by  an  authorised  person.  Repairs  carried  out  by  an 
unauthorised  person  may  cause  abnormal  operation.  The  heater  must  be  serviced  at  least  once  every 
three (3) years. 

Danger 

Warnings 

Содержание PJC-W18FR

Страница 1: ...be installed in accordance with a Local Gas Fitting Regulations b Municipal Building Codes c Australian Standard for Gas Appliance Installations AS5601 2004 d Any other relevant Statutory Regulation...

Страница 2: ...components supplied by the manufacturer It does not apply to components supplied by others Where a failed component is replaced under warranty the balance of the original appliance warranty will remai...

Страница 3: ...rrying the heater Warning Label Rating Plate Shows model No Gas Type Month of Manufacture Warm Air Inlet Warm air is discharged Louvre Air Filter 1 Prevents dust entering the appliance Gas Hose Electr...

Страница 4: ...e correctly fitted 3 Replace access panel and gently push into position TIMER1 BUTTON TIMER2 BUTTON TEMPERATURE ADJUSTMENT BUTTON OVER RIDE BUTTON CHILD LOCK LIGHT ON OFF BUTTON FILTER LIGHT SET TIMES...

Страница 5: ...e heater Low Emission Technology Class 1 Appliance AS4553 2008 Less than half the emissions of the Australian Standard Energy efficient 7 stage modulating gas valve Manufactured in Japan Safety Device...

Страница 6: ...Capacity Maximum Sq m 97 70 Minimum Room Sizing Cu M 62 5 45 Test Point Pressure NG kPa 0 86 0 47 LPG kPa 2 0 1 2 Test Point Pressure at Turndown NG kPa 0 13 0 13 LPG kPa 0 3 0 3 Injector Sizes NG mm...

Страница 7: ...red by the Victorian Building Act 1993 Only a licensed person will give you a compliance certificate showing that the work complies with all relevant standards Only a licensed person will have insuran...

Страница 8: ...correctly ventilated while unit is operating Continuous use decreases the oxygen level in the room which activates the oxygen depletion safety system Do not allow curtains or other flammable materials...

Страница 9: ...ter near an opening door The heater could be knocked over Do not touch the electric plug with wet hands as this could cause an electric shock Do not pull the electrical cord to unplug as this could br...

Страница 10: ...er Do not install where water may splash or near another heat source Do not install in a caravan mobile home or recreational vehicle Do not connect to a Propane LPG gas cylinder indoors This appliance...

Страница 11: ...e temperatures inside the heater and is normal Please do not unplug the heater while the fan is still operating Important Information When using the heater for the first time or after long periods of...

Страница 12: ...uttons For Eg Select 22 Degrees C as your desired temperature and this temperature is then memorised into the control system SET temperature selection can range from 16 Degrees C low 26 Degrees C high...

Страница 13: ...peration is switched OFF Over ride light glows ON OFF light glows green and timers are ready After the heater turns off the convection fan will continue to operate for up to 4 minutes Do not unplug wh...

Страница 14: ...or 11 12am 1 Adjust the hour Keep pressing the adjustment button until 11 00am is displayed 2 Adjust the minute Press the adjustment button again until 11 12am is displayed Press SET TIMES five times...

Страница 15: ...ime press the down or up button until the correct time is reached Example To set the TIMER 1 ON time to 5 30AM 1 Adjust the hour 2 Keep pressing the adjustment button until 5 00AM is displayed 3 Adjus...

Страница 16: ...adjustment button until 8 10PM is displayed Press SET TIMES button TIMER 2 OFF light flashes TIMER 2 OFF time is displayed on the screen Adjust TIMER 2 OFF time as required To set the TIMER 2 OFF time...

Страница 17: ...lete the process Press The TIMER1 and or TIMER 2 button s as follows You can select TIMER 1 or TIMER 2 or both by pressing the TIMER 1 and or TIMER 2 buttons Selected TIMER s ON OFF lights will glow T...

Страница 18: ...ock the air outlet Press the TIMER S button s You can select TIMER 1 or TIMER 2 or both by pressing the TIMER 1 and or TIMER 2 buttons Selected TIMER s ON OFF lights will glow The TIMER operation is n...

Страница 19: ...e timers are overlapped the time that is set first will have priority and the timer set second will be cancelled The timer settings will continue to operate if they are not cancelled PRE HEAT FUNCTION...

Страница 20: ...stops after the temperature inside the heater has cooled No action required The heater creaks at the time of lighting or switching off The sound is caused by expansion and contraction of metallic part...

Страница 21: ...lem persists call for service The gas supply volume is inadequate Call for a licensed plumber Thermo switch is off Call for service Air Filter is clogged Clean Air Filter and operate again If problem...

Страница 22: ...2 Air filter is fitting correctly and is not dirty 3 The hose is correctly connected without kinking or twisting 4 There is no damage to the electric cord Maintenance Caution Wear gloves Be careful of...

Страница 23: ...ashes clean Air Filters 1 and 2 Use a vacuum cleaner to remove dirt on the Air Filters Air Filter 1 could be taken off to clean Use mild soapy water for severe dirt and refit after drying If Air Filte...

Страница 24: ...4961 3515 03 9212 8911 08 8343 0044 08 9351 4290 Parts Fax 07 3412 9219 02 9684 9188 02 4961 3117 03 9212 8984 08 8359 6003 08 9351 4614 Service Email qld service rhee m com au nsw service rhee m com...

Отзывы: