background image

28

Draining the Water Heater

Freeze Protection

Where the water heater may be exposed to
freezing conditions, even for a short
period of time, be sure to drain all water
from the unit as instructed above.

Exposure to freezing conditions can occur
from down draft of venting system or
from installation in areas exposed to cold
air.
The water heater is equipped with a Freeze

Protection Electric Heater. As long as the

electricity is supplied to the water heater, it

prevents freezing inside the water heater up

to an ambient temperature of approximately

minus 30°F (without wind-chill factor)
This device only protects the internal

components of the water heater. It does

NOT protect piping and valves. Therefore,

piping and valves should be wrapped with

insulation material as instructed on page 21.

Another method of freeze prevention is by

running a small volume of water.  Running

water will protect the water heater, piping

and valves.
Follow the steps below to ensure proper

water flow through the water heater and

piping:

Turn off the switch on the remote
control.

Close the gas shut-off valve.

Open the hot water faucet slightly until
a stream of approximately 1/8” is
flowing.  Be sure to check the flow
periodically.

WARNING: Failure

to drain the water

heater can cause serious

damage to the water

heater as well as

personal injury.

!

Below are instructions for draining water
out of the water heater.

Turn off the switch on the remote
control.

Close the gas shut-off valve(s).

Unplug the power supply cord (or
disconnect breaker) at least 10 seconds
after step #1.

Open all hot water faucets. Before
proceeding to the next step, make sure
that COLD water is coming out of all
hot water faucets.

Close the water shut-off valve.

Using a suitable container to catch
water, remove the water filter from
heater. Attach a garden hose to the
drain valve installed in the hot water
outlet line and direct the stream of
water to a suitable drain where it will
cause no damage.  Approximately 21oz
of water will be drained. Leave water
heater as is until next use.

To put the water heater back into
operation after draining, follow the steps
below.

Reinstall the drain plug and water filter.
Close the hot water outlet drain valve.

Open the water shut-off valve and close
again after making sure that water
comes out from hot water faucets.
(This step is to remove air from the
water lines.)

Plug into an electrical outlet, fully open
the gas shut-off valve and the water
shut-off valve.

NOTICE:

The water heater may not

operate unless the above procedure is
followed correctly.

To Hot Water

Faucet(s)

°F

PRIORITY

POWER

ON/OFF

Draining the water heater

WARNING: Failure

to follow these

instructions while

draining the water

heater can cause serious

damage to the water

heater as well as

personal injury

including scalding.

!

NOTICE

: DO NOT

unplug the electric

power supply cord for

freeze protection.

Care and cleaning of the water heater.

Содержание PH-28RIFSN

Страница 1: ...installation and adjustment of the water heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also...

Страница 2: ...READ THIS MANUAL FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is...

Страница 3: ...hesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity...

Страница 4: ...water temperature is recommended to reduce the risk of scald injury Contact a licensed plumber or the local plumbing authority for further information Notice The factory setting allows operating tempe...

Страница 5: ...r LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to lo...

Страница 6: ...ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage personal i...

Страница 7: ...reduce BUT NOT eliminate the possibility of lighting the vapor of any flammable liquids which may be improperly stored or accidentally spilled The water heater should be installed as close as practica...

Страница 8: ...warranty is voided when failure of the heater is due to operation in a corrosive atmosphere NOTICE The water heater should not be installed near an air supply containing halogenated hydrocarbons Inspe...

Страница 9: ...water supply lines DO NOT cover the drain valves To ensure proper operation of the water heater the following water pressure guidelines should be followed Operation of the water heater requires the mi...

Страница 10: ...ter damage Notice If the relief valve on the system discharges periodically a problem exists and service to the water system is required Water Supply Connections Continued Install a shutoff valve near...

Страница 11: ...be installed at the gas connection of the water heater at the time of installation see diagram to the left The branch gas supply line to the water heater should be clean 3 4 black steel pipe or other...

Страница 12: ...air supply for proper operation as outlined in the Venting section of this manual WARNING Use UL approved Category III Stainless Steel vent material only No other vent material is permitted WARNING Re...

Страница 13: ...tructions before installation Test fit the adapter over the water heater collar before proceeding Adjust clamp as needed With an alcohol wipe clean inside surface A of adapter and outside surface of B...

Страница 14: ...Not terminate vent pipe directly on brick or masonry surfaces Use a rust resistant sheet metal backing plate 2 x 2 feet behind vent See illustration Do Not locate vent terminal too close to shrubbery...

Страница 15: ...board or other composite material Use 4 10x1 1 4 wood screws for plywood solid wood sheathing or members Use suitable masonry anchors when passing through solid masonry walls Reinstall the decorative...

Страница 16: ...f condensate in accordance to local codes Rain Cap Storm Collar Support Clamp 1 4 per foot downward slope 2 Max Chase Requires 6 Clearance to Combustibles Firestop Firestop Roof Jack Adjustable Roof F...

Страница 17: ...tween the water heater and the remote control s installation location is limited to 195 feet of wire NOTICE Only one of each type of remote controls can connect to the water heater Therefore a maximum...

Страница 18: ...upwards Connect the remote control cables to the extension cable from the water heater Place the remote control over the base plate Ensure the projections in the base plate fit into the housings in t...

Страница 19: ...W BR AIR INTAKE FILTER SWITCH TRANSFORMER GND BK GND WATER FLOW SENSOR OVER HEAT LIMITER BK BLACK COLOUR CODE BR BROWN R RED W WHITE B BLUE GY GRAY GR GREEN O ORANGE Y YELLOW G Y GREEN YELLOW REMOTE...

Страница 20: ...liance Shut off supplied Sediment Trap Manual Gas Supply Line Shut off Valve Union Cap Cold Water Supply Shut off Valve Check Valve Vent Adapter F PRIORITY POWER ON OFF Remote Control Power Supply Cor...

Страница 21: ...er Hot and Cold Pipe Insulation Installation Gas Inlet Check Valve Inlet Pipe Cold Water Hot Water Insulate all the way to the top Insulation Blankets Insulation blankets available to the general publ...

Страница 22: ...Supply Gas type matches rating plate Gas supply pressure is sufficient for the water heater Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and wa...

Страница 23: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Страница 24: ...educing point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed plumber or the local plumbing authority for further information See page 4 for more details...

Страница 25: ...ter Always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald injury Always supervise young children or others who are incapaci...

Страница 26: ...ice After inspection maintenance and or cleaning ensure proper operation by turning on a hot water faucet Housekeeping Before performing Housekeeping tasks to this water heater turn the unit off and d...

Страница 27: ...be turned off The water heater and piping should be drained if they might be subjected to freezing temperatures After a long shut down period the water heater s operation and controls should be check...

Страница 28: ...ns for draining water out of the water heater Turn off the switch on the remote control Close the gas shut off valve s Unplug the power supply cord or disconnect breaker at least 10 seconds after step...

Страница 29: ...etely The main burner goes off when incoming water volume is inadequate Check that proper power is being supplied and or water supply is adequate Fan continues to rotate after hot water faucet is clos...

Страница 30: ...t water faucet once The water heater can then be used The Gas Shutoff Valve is not opened completely Gas Service has been interrupted LP Gas is running low LP models only Contact Gas Utility Company F...

Страница 31: ...ls using natural or LP gas Instructions For Placing a Parts Order Address parts orders to the distributor or store from where the water heater was purchased All parts orders should include The model a...

Страница 32: ...all of the other component parts warranty will be limited to one 1 year from the Effective Date WARRANTY EXCLUSIONS This Limited Warranty will not cover a Service trips to your home to teach you how t...

Страница 33: ...ines that a defect exists Paloma shall furnish replacement part s in full settlement of its warranty obligations Purchasers shall be required to return at purchasers expense the defective part s to th...

Страница 34: ...140 F With Main Control Dip Switch Combustion System Fan Assisted Combustion Main Burner Bunsen Type Burner Ignition Electric Continuous Sparking Ignition Electric Portion Electric Rating 120 VAC 60Hz...

Страница 35: ...This page was intentionally left blank...

Страница 36: ...Paloma Industries Inc 2151 Eastman Avenue Oxnard CA 93030 PRINTED IN JAPAN 31 50641...

Отзывы: