background image

6

MISO 48 FIREBOWL Electronic Ignition | Installation & Owner's Manual

ASSEMBLY

TO ASSEMBLE THE FIRE PIT

1.  Connect the Burner Assembly to the gas/propane 

supply using the supplied flex connector and following 

the instructions on page 8.

2.  Carefully leak test all connections following the 

procedure on page 8.

3.  Fill the burner pan evenly with burner media (crushed 

tempered glass for natural gas; volcanic rock for 

propane). Do not obstruct the pilot lighting port with 

burner media! Use burner media supplied by Paloform 

only!

4.  Follow the Initial Lighting Instructions on page 9. 

Make sure that the flame carries to all parts of the 

burner. Turn OFF the appliance and let it cool before 

proceeding to the next step.

5.  Place Topping Ring. Evenly distribute decorative 

topping (river stones, crushed glass or lava rock) on 

top of burner media. An uneven or excessively thick 

layer of topping can result in an uneven flame.

6.  Do not cover pilot shield. Keep the lighting port open 

and free of media. Do not use any media not supplied 

by the manufacturer!

BURNER MEDIA

DECORATIVE TOPPING

IGNITION PORT:

DO NOT OBSTRUCT

CORRECT FLAME APPEARANCE

WARNING:

Failure to position parts in 

accordance with these diagrams 

and instructions and/or failure to 

use parts specifically approved for 

use with this appliance may result 

in property damage or personal 

injury.

Do not remove the data plates 

attached to the Outdoor Fire Pit 

Burner. These plates contain 

important information.

NOTICE: 

Installation and repair should 

be done by a qualified service 

person. The appliance should be 

inspected before use and at least 

once annually by a qualified service 

person. More frequent cleaning 

may be required as necessary. 

It is imperative that control 

compartment, burner ports and 

circulating air passageways of the 

appliance be kept clean.

CAUTION: 

New Lava Rock may pop or crackle 

when first heated. This should 

subside after 30 minutes to one 

hour or more of operation. Maintain 

safe distance during this time.

Содержание MISO 48

Страница 1: ...WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this man...

Страница 2: ...Code ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fue...

Страница 3: ...S ELECTRICAL 1 UNPACK Account for all parts see p 14 2 FRAGILE Handle with care 3 LEVEL Place on a solid level surface 4 AIR VENTS Do not block ventilation holes in base see p 4 5 GAS ELECTRICAL Suppl...

Страница 4: ...R E 24 CIR E 24P Max Heat Input 140 000 BTU h 140 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size J 27 Burner Ports 114 114 Port Size 1 8 1 8 Electrical...

Страница 5: ...5 MISO 48 FIREBOWL Electronic Ignition Installation Owner s Manual FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 82 11 0 CLEARANCE BELOW...

Страница 6: ...ult in an uneven flame 6 Do not cover pilot shield Keep the lighting port open and free of media Do not use any media not supplied by the manufacturer BURNER MEDIA DECORATIVE TOPPING IGNITION PORT DO...

Страница 7: ...S FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION Do n...

Страница 8: ...an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressu...

Страница 9: ...lified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or ma...

Страница 10: ...manual gas control valve to the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing...

Страница 11: ...least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all times Remove pilot cover to inspec...

Страница 12: ...ITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is smok...

Страница 13: ...clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace pilot...

Страница 14: ...12 same 9 CIR Control Box see drawing same 10 Control Box Chassis CIR E CHA same 11 Power Adapter 120V NA not shown E POW 24VAC same 12 Burner Media not shown Crushed Glass 25 kg Lava Pebbles 18 L 13...

Страница 15: ...R CIR E 24 BOX same 2 Dual Solenoid Valve C BUR E VAL BASO 278 w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Street Elbow 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip...

Страница 16: ...USTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E 410...

Страница 17: ...option replace or repair the defective components at no charge to the original owner Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components Any products p...

Отзывы: