TROUBLESHOOTING cont’d

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When power is turned on, nothing 

happens

1.  No power to unit

1.  Check connections between 

controls, power adapter and 

power source

2.  Check power at source

3.  Verify that power adapter is 

functioning correctly

4.  If you are using a third-party 

remote control unit, verify that 

this unit is functioning correctly

When power is turned on, there is a 

spark at pilot but no ignition

1.  Gas supply turned off or manual 

shutoff valve closed

2.  Air in gas lines when installed

3.  Pilot is clogged

4.  Pilot valve lead is loose/

disconnected

1.  Turn off gas supply or open 

manual shutoff valve

2.  Purge air from the supply line

3.  Clean pilot (see Cleaning and 

Maintenance, page 11) or replace 

pilot assembly

4.  Check/reconnect lead

Burner does not light after pilot is lit

1.  Burner orifice is clogged

2.  Inlet gas pressure is too low                  

3.  Flame sensor or Main Valve lead 

loose/disconnected

4.  Ignition Control Board failure

1.  Clean burner orifice

2.  Contact local gas or propane 

supplier

3.  Reconnect / replace lead 

4.  Replace Board

Delayed burner ignition

1.  Lighting port is blocked

1.  Remove burner media/debris 

from Lighting Port

Burner flame is too low or too high

1.  Incorrect gas supply or pressure

2.  Blocked burner orifice or burner 

ports

3.  Improper burner orifice size

1.  Check for proper gas supply 

pressure

2.  Free burner orifice and burner 

ports of any burrs, paint, or other 

blockage

3.  Verify proper burner orifice sizing 

(see page 4)

Содержание MISO 48

Страница 1: ...WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this man...

Страница 2: ...Code ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fue...

Страница 3: ...S ELECTRICAL 1 UNPACK Account for all parts see p 14 2 FRAGILE Handle with care 3 LEVEL Place on a solid level surface 4 AIR VENTS Do not block ventilation holes in base see p 4 5 GAS ELECTRICAL Suppl...

Страница 4: ...R E 24 CIR E 24P Max Heat Input 140 000 BTU h 140 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size J 27 Burner Ports 114 114 Port Size 1 8 1 8 Electrical...

Страница 5: ...5 MISO 48 FIREBOWL Electronic Ignition Installation Owner s Manual FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 82 11 0 CLEARANCE BELOW...

Страница 6: ...ult in an uneven flame 6 Do not cover pilot shield Keep the lighting port open and free of media Do not use any media not supplied by the manufacturer BURNER MEDIA DECORATIVE TOPPING IGNITION PORT DO...

Страница 7: ...S FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION Do n...

Страница 8: ...an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressu...

Страница 9: ...lified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or ma...

Страница 10: ...manual gas control valve to the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing...

Страница 11: ...least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all times Remove pilot cover to inspec...

Страница 12: ...ITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is smok...

Страница 13: ...clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace pilot...

Страница 14: ...12 same 9 CIR Control Box see drawing same 10 Control Box Chassis CIR E CHA same 11 Power Adapter 120V NA not shown E POW 24VAC same 12 Burner Media not shown Crushed Glass 25 kg Lava Pebbles 18 L 13...

Страница 15: ...R CIR E 24 BOX same 2 Dual Solenoid Valve C BUR E VAL BASO 278 w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Street Elbow 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip...

Страница 16: ...USTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E 410...

Страница 17: ...option replace or repair the defective components at no charge to the original owner Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components Any products p...

Отзывы: