background image

10

CALDERA CORTEN Electronic Ignition | Installation & Owner's Manual

LIGHTING YOUR FIRE PIT

OPERATING INSTRUCTIONS

1.  STOP!  Read the safety information on pages 1, 2 and 9 of this manual.
2.  Turn off all electric power to the appliance.
3.  Do not attempt to light the pilot manually.
4.  Turn the manual gas control valve to the OFF position.
5.  Wait five (5) minutes to clear out any residual gas, then check for the smell of 

gas at and around the appliance, including near the floor.  If you smell gas, 

STOP!  Follow the instructions on page 1 of this manual.  If you do not smell 

gas, continue to the next step.

6.  Turn the manual gas control valve to the ON position.
7.  Plug the supplied 24 VAC AC adapter into a 110V power outlet.
8.  Connect the AC adapter to the AC input plug at the unit.
9.  Place Burner Assembly in Housing
10. To ignite burner, turn on electric power to the appliance.
11. To turn off appliance, turn off electric power to the appliance.

TURNING OFF THE GAS TO THE APPLIANCE

1.  Turn off all electric power supplied to the appliance if service is to be 

performed.  Unplug the 24 VAC AC adapter from the power outlet.

2.  If necessary, remove the burner from the housing to access the manual gas 

valve.

3.  Turn the main manual shutoff valve to the full OFF position.

WARNING:

This appliance is designed to be connected to a power 

source that is controllable by a switch.

Do not connect 24 VAC AC adapter to a live power source.

Содержание Caldera-E NG

Страница 1: ...NGER WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Burner conforms to ANSI Z21 97 CSA 2 41 2017 Outdoor Decorative Gas Appliances CSA 2 17 2017 Gas fired Appliances For Use at High Altitudes We recommend that our fire pits...

Страница 2: ... Code ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appliance Do not use this appliance to cook food or to burn paper or other objects 5 Children and adults should be alerted to the hazards of high surface temperatures and should stay away to...

Страница 3: ...weather conditions Rust will bleed until it stabilizes Do not place Cor Ten fire pits on surfaces that will be permanently damaged or stained by rust bleed 1 UNPACK Account for all parts see p 14 2 FRAGILE Handle with care 3 LEVEL Place on a solid level surface 4 AIR VENTS Do not block ventilation holes in base see p 4 5 GAS ELECTRICAL Supply lines are routed through the base of the unit and must ...

Страница 4: ...9 000 BTU h 60 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size 18 37 Burner Ports 68 68 Port Size 1 8 1 8 Electrical 120V 15A Outdoor Receptacle Dedicated Circuit with Wall Switch Burner connects via an AC adapter Must be installed and grounded in accordance with local codes VENTILATION HOLES GAS SUPPLY OPENING ...

Страница 5: ...5 CALDERA CORTEN Electronic Ignition Installation Owner s Manual FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 72 72 8 7 BOL CALDERA 0 CLEARANCE BELOW ...

Страница 6: ...utes to one hour or more of operation Maintain safe distance during this time TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply using the supplied flex connector and following the instructions on page 8 2 Carefully leak test all connections following the procedure on page 8 3 Cover the burner evenly and completely with burner media crushed tempered glass for natural ...

Страница 7: ...EROCK BOULDERS OPTIONAL ARRANGE OVER BURNER RING TO OPTIMIZE FLAME APPEARANCE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION Do not use any media over the burner that have not been supplied by Paloform Landscape stone or other natural or manufactured materials may explode when heated ...

Страница 8: ...an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures in Excess Of 1 2 psi 3 5 kPa This appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in ...

Страница 9: ...lified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or maintenance can result in injury or property damage For assistance or additional information consult a qualified installer service agency or the gas supplier Do not store or use gasoline or other flamma...

Страница 10: ...manual gas control valve to the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing 10 To ignite burner turn on electric power to the appliance 11 To turn off appliance turn off electric power to the appliance TURNING OFF THE GAS TO THE APPLIANCE 1 Turn off all electric power supplie...

Страница 11: ... at regular intervals at least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all times Remove pilot cover to inspect pilot Remove topping from top of burner ring and Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner PILOT FLAME The flames fro...

Страница 12: ...ITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is smoking sooting excessively Note It is natural and unavoidable for appliance sets to produce moderate levels of carbon soot where flames contact the media 1 Poor fuel quality 2 Excessive flame impingement...

Страница 13: ...clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace pilot assembly 4 Check reconnect lead Burner does not light after pilot is lit 1 Burner orifice is clogged 2 Inlet gas pressure is too low 3 Flame sensor or Main Valve lead loose disconnected 4 Ignition Co...

Страница 14: ...pter 8 Flex Connector CON SS 5MM 12 same 9 CIR Control Box see drawing same 10 Control Box Chassis CIR E CHA same 11 Power Adapter 120V NA not shown E POW 24VAC same 12 Burner Media not shown Crushed Glass 17 5 kg Lava Pebbles 15 L 13 Topping Media not shown Various Various 14 Fabric Cover not shown COV CAL45 LC same 15 Corten Vessel not shown CAL45 10 same WARNING Failure to position parts in acc...

Страница 15: ... CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Street Elbow 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignition Control Board E BOARD CC9 same 9 3 8 Flare Adapter 10 3 8 Close Nipple 11 Barrel Connector part of wiring harness 12 Wiring Harness not shown E WIR KIT same 1 2 3 9 5 10 11 1a 9 6 7 4 8 ...

Страница 16: ...USTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E 410 OR PIL E 410LP IGNITION CONTROL BOARD E BOARD CC9 GAS VALVE E VAL BASO ...

Страница 17: ... option replace or repair the defective components at no charge to the original owner Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components Any products presented for warranty repair must be accompanied by a dated proof of purchase This Warranty will be void if the appliance is not installed by a qualified installer in accordance with installation inst...

Отзывы: