![PaloAlto Networks M-300 Скачать руководство пользователя страница 36](http://html2.mh-extra.com/html/paloalto-networks/m-300/m-300_hardware-reference-manual_3355921036.webp)
Service the M-300 or M-700 Appliance
The following procedure describes how to replace a log drive on an M-300 or M-700
appliance that is in Panorama
™
mode or Panorama log collector mode. This procedure
does not apply to an appliance in PAN-DB mode (
M-700 only
) or Panorama Management-
only mode because the front log drives are not used for these modes.
STEP 1 |
Idenfy the failed drive and record the drive model number by running the following
operaonal command and viewing the
status
and
model
fields:
admin@hostname>
show system raid detail
For example, the following output shows that disk drive A2 failed and the drive model is
ST8000NM0055-1RM.
Disk Pair A Available
Status clean, degraded
Disk id A1 Present
model : ST8000NM0055-1RM
size : 7630885 MB
status : active sync
Disk id A2 Present
model : ST8000NM0055-1RM
size : 7630885 MB
status : failed
STEP 2 |
Remove the failed drive from the RAID 1 array. In this example, run the following command
to remove drive A2 from the array:
admin@hostname>
request system raid remove A2
M-300 and M-700 Appliance Hardware Reference
36
©
2022 Palo Alto Networks, Inc.