6.1.2.5. Connection to ONDEIS (Rain) sensor
•
Rain sensor requires a dry contact input. Our single motors (ALTUS) works with RTS
•
In order to use ONDEIS rain sensor you must use Dry Contact Transmitter
•
The RTS motors can communicate with dry contact transmitter or RS485 (multiple dry
contact transmitter. Up to 5 channels.) Then dry contact transmitter communicates with
ONDEIS Rain sensor and also RTS motors.
•
The ONDEIS Rain sensor has a
two-cable output. One cable
must go to main voltage
(230V/50Hz) and other is to dry
contact signal cable.
•
You must joint rain sensor dry
contact cable to RS485’s channel
input jacks (from 1 to 5)
•
In this case there is only one
solution, if your products
have more than 2 rails you
can upgrade to tandem motor
system. Otherwise, there is no
solution.
When you plug all cables now
you can program to rain sensor.
Select the RTS address on the
channel selector corresponding
to dry contact connectors.
•
Press to PROG button on your remote control
•
Then press PROG button on RS485 or Dry Contact Transmitter.