Erase all the sensors and record a new one;
•
Press more than 7 sec. on the “prog” button of the new EOLIS RTS sensor.
•
The pergola moves shortly (DOWN/UP)
6.1.1.3. Functioning
The WIND threshold can be adjusted by a potentiometer accommodate wind speed between
10 to 50km/h (6 to 31mph)
•
When the wind speed exceeds the threshold set by the EOLIS sensor RTS, an UP
order is given to the pergola after 2 sec.
•
As long as the measured wind speed is higher than the adjusted threshold, any
order is inhibited.
•
When the wind speed falls below the threshold setting, an order can be given
with the RTS control after 30 sec.
6.1.2. Single Motor Connection to SOLIRIS RTS (Sun and Wind Sensor)
On Orea RTS Motor connection to SOLIRIS RTS (Sun & Wind Sensor).
6.1.2.1. Programming
•
The motor must be in programming mode to record a SOLIRIS RTS Sensor
•
One SOLIRIS RTS Sensor can be memorized into several motors.
•
It isn’t recommended to memorize more than 1 SOLIRIS RTS Sensor into motor’s memory.
•
To Enter the Programming mode;
•
Activate the receiver’s memory by pushing (for more than 2 seconds) the
programming button of a transmitter already recorded in the motor’s memory.
•
To Record or delete a sensor ;
•
Press briefly on the programming button of the SOLIRIS RTS briefly sensor.
•
To delete all the sensors and record a new one;
•
Press for more than 7 sec. on the “programming” button of the new SOLIRIS
RTS.