background image

9

Re-Load Instructions RevD

Toll Free: 800-788-1028  •

  

www.NomadFlexibleFurniture.com

6. Discharging of battery

6.1   As mobile devices get “Reloaded” from the charging hub, the battery will begin to 
slowly discharge.
6.2   When the BLUE LED is lit, this means the internal battery power status is in the range 
from 100% to 10%.
6.3   When the RED LED is lit the battery power status is below 10% and needs to be 
charged.  (The Re-Load hub will continue to “Reload” while LED is RED).
6.4   When there is NO colored LED lit, this means the circuit has shut-off and the internal 
battery needs immediate charging of the battery.  The Re-Load hub will not charge devices in 
this status.
6.5   Please refer to above instructions for charging battery during use, instruction 4.9.

NOTE: 

 While NO colored LED’s are lit, the battery retains a minimal power level.  This 

protects the battery from a deep discharge.  Batteries that go into a deep discharge state 
have a shortened life cycle.  A safe battery shut-off is integrated into the circuitry of Re-
Load.   This allows the Re-Load battery a longer and safer life cycle.  Under normal working 
conditions and proper maintenance, the battery should last 3+ years.

7. Removing internal battery

Over duration of using the ReLoad table it might be necessary to remove the internal battery. 
Please follow below instructions for easy removal.

7.1   Gain access to the battery compartment by unlocking the handle with the key provided. 
(Figure A, page 4, #08)
7.2   Pull back on the handle to release worksurface and tilt vertical.
7.3   Locate internal battery in the compartment.
7.4   Make sure all wire connections have been released from each other.
7.5   Locate Velcro strap and loosen the strap.
7.6   Locate vinyl strap on battery, slide hand between strap and battery pull upward.  Use 
your other hand to lift battery and get firm hold on it.  Battery weighs 13 lbs. so please DO 
NOT DROP.
7.7   To place battery back into compartment, make sure Velcro strap is flipped back on each 
side so the battery fits between.
7.8   Make sure all wires and wire connections are not under battery.
7.9   Tighten Velcro strap to hold battery back in place.

PLEASE RECYCLE OLD BATTERIES BY CONTACTING 1-800-BATTERY FOR LOCAL DROP-
OFF LOCATIONS OR PICKUP SERVICES.

Содержание Nomad Re-Load Mobile Table with Charging...

Страница 1: ...bleFurniture com READTHIS ENTIRE MANUAL BEFORE OPERATINGTHISTABLE FAILURETO DO SO COULD RESULT IN SERIOUS INJURY DAMAGETOTHE CHARGING DEVICES ANDTHETABLE WARNING Operational Manual 12V DC Power Source...

Страница 2: ...NING SECTION PAGE 1 Re Load Parts Schematic 4 2 Safety Instructions 5 3 Personal Precautions 6 4 Charging the Re Load Battery Pack 7 5 Using your Re Load 8 6 Discharging of Battery 9 7 Removing Intern...

Страница 3: ...d in certain situations DANGER Indicates an immediate hazardous situation This will result in serious injury or death of operator or bystanders WARNING Indicates a potentially hazardous situation This...

Страница 4: ...rness A 03 PU BATTERY 1 12v RE LOAD battery pack 04 PU CHARGER 1 12V RE LOAD charger 05 Varies per table size 30 Squircle worksurface 06 Varies per table size Upper welded assembly battery compartment...

Страница 5: ...battery connector or charging hub This will damage the connectors and cause personal injury 2 4 DO NOT OPERATE Re Load table if it has received a sharp blow has been dropped or otherwise damaged Conta...

Страница 6: ...produce a short circuit high enough to weld a ring bracelet etc to the metal causing severe burns 3 4 DO NOT OPERATE the Re Load table with damaged wires Unplug the table and contact Palmer Hamilton...

Страница 7: ...5 Locate and connect the B wire connector Charger to the C wire connector Battery see below Figure B 4 6 Align the connectors and gently push together 4 7 Locate and plug the 2 pronged plug into a st...

Страница 8: ...compartment and not in the way of getting pinched Figure A page 4 06 5 5 Push in lock to lock handle Remove key Your Re Load is now ready for use NOTE The Re Load table will charge many devices inclu...

Страница 9: ...Load This allows the Re Load battery a longer and safer life cycle Under normal working conditions and proper maintenance the battery should last 3 years 7 Removing internal battery Over duration of u...

Страница 10: ...tly on the caster lever with your foot To disengage push gently on the upper caster lever There is a slight movement in the caster lever while locking or unlocking 9 1 The Re Load worksurface is made...

Страница 11: ...10 2 All batteries are affected by temperature The ideal storage temperature is 70 F The internal battery will gradually self discharge lose power over time especially in warm cold environments To en...

Страница 12: ...e has been blown Circuit pulled too much power Replace fuse contact PH Battery is defective Need new battery contact PH PCB defective Replace Charging hub contact PH Casters won t lock Mechanical lock...

Страница 13: ...l manual are followed This warranty is VOIDED if repairs have been made or attempted by anyone other than Palmer Hamilton and its authorized personnel If alterations have been made to the product usin...

Страница 14: ...on Street Elkhorn WI 53121 1911 Toll Free 800 788 1028 Local 262 723 8200 Fax 262 723 5180 www NomadFlexibleFurniture com To see the complete family of Palmer Hamilton products please see www palmerha...

Отзывы: