background image

7

Re-Load Instructions RevD

Toll Free: 800-788-1028  •

  

www.NomadFlexibleFurniture.com

IMPORTANT:  CHARGE THE INTERNAL BATTERY IMMEDIATELY AFTER RECEIVING YOUR 
RE-LOAD TABLE.  IF NOT IN USE, CHARGE MONTHLY TO MAINTAIN THE FULL BATTERY 
LIFE. *SELF-CHARGING RE-LOAD TABLES (SC) WILL INCLUDE A CHARGER IN THE BATTERY 
COMPARTMENT.  *STANDARD RE-LOAD TABLE (DC) DOES NOT INCLUDE A CHARGER.  
PH RECOMMENDS A BATTERY CHARGING CART TO BE PURCHASED WITH DC RELOADS 
TABLES.  A SEPARATE CHARGER IS AVAILABLE FOR PURCHASE FROM PH. 
THE INSTRUCTIONS BELOW ARE FOR THE SELF-CHARGING (SC) OR A SEPARATE 
CHARGER.

4.1   When it is time to charge the battery the Hub LED should be RED or no color at all.           
RED LED indicates battery has little power remaining.  No LED’s lit means that battery has 
reached shut off point and will no longer charge devices.
4.2   Gain access to the battery compartment by unlocking the handle with the key provided. 
(Figure A, page 4, #08)
4.3   Pull back on the handle to release worksurface and tilt vertical.
4.4   Gently pull wire connections “A” & “C” apart, if applicable.
4.5   Locate and connect the “B” wire connector (Charger) to the “C” wire connector (Battery)-
see below Figure B.  
4.6   Align the connectors and gently push together.
4.7   Locate and plug the 2-pronged plug into a standard 120V wall outlet to begin the charging.
4.8   The charger will scan the battery to check capacity level and then commence charging.  
The GREEN LED light on the charger indicates the charging status.
4.9   Once all the GREEN LED lights are lit solid, the battery is fully charged.  It is safe to 
leave charger connected to the battery as it will go into a trickle mode or only when needed to 
maintain the battery at 100%.
4.10   Leave worksurface open vertical 
while charging.  If not possible, carefully 
route the charger cord so that it is not 
pinched when closing top.  Weave the 
cord thru the corner area of the battery 
compartment, and gently lower the 
worksurface down until latched.
4.11   When charging is complete, unplug 
cord from the wall outlet, unplug the 
charger/battery connection by gently 
pulling the “B” wire connector and “C” 
wire connector apart.  DO NOT damage 
the wire connection by pulling directly on 
the wires, pull only on the connectors’ 
plastic housing.

4. Charging the Re-Load table battery pack

A

B

C

Figure B 

 

A=Wire A 

B= Wire B  C=Wire C

Содержание Nomad Re-Load Mobile Table with Charging...

Страница 1: ...bleFurniture com READTHIS ENTIRE MANUAL BEFORE OPERATINGTHISTABLE FAILURETO DO SO COULD RESULT IN SERIOUS INJURY DAMAGETOTHE CHARGING DEVICES ANDTHETABLE WARNING Operational Manual 12V DC Power Source...

Страница 2: ...NING SECTION PAGE 1 Re Load Parts Schematic 4 2 Safety Instructions 5 3 Personal Precautions 6 4 Charging the Re Load Battery Pack 7 5 Using your Re Load 8 6 Discharging of Battery 9 7 Removing Intern...

Страница 3: ...d in certain situations DANGER Indicates an immediate hazardous situation This will result in serious injury or death of operator or bystanders WARNING Indicates a potentially hazardous situation This...

Страница 4: ...rness A 03 PU BATTERY 1 12v RE LOAD battery pack 04 PU CHARGER 1 12V RE LOAD charger 05 Varies per table size 30 Squircle worksurface 06 Varies per table size Upper welded assembly battery compartment...

Страница 5: ...battery connector or charging hub This will damage the connectors and cause personal injury 2 4 DO NOT OPERATE Re Load table if it has received a sharp blow has been dropped or otherwise damaged Conta...

Страница 6: ...produce a short circuit high enough to weld a ring bracelet etc to the metal causing severe burns 3 4 DO NOT OPERATE the Re Load table with damaged wires Unplug the table and contact Palmer Hamilton...

Страница 7: ...5 Locate and connect the B wire connector Charger to the C wire connector Battery see below Figure B 4 6 Align the connectors and gently push together 4 7 Locate and plug the 2 pronged plug into a st...

Страница 8: ...compartment and not in the way of getting pinched Figure A page 4 06 5 5 Push in lock to lock handle Remove key Your Re Load is now ready for use NOTE The Re Load table will charge many devices inclu...

Страница 9: ...Load This allows the Re Load battery a longer and safer life cycle Under normal working conditions and proper maintenance the battery should last 3 years 7 Removing internal battery Over duration of u...

Страница 10: ...tly on the caster lever with your foot To disengage push gently on the upper caster lever There is a slight movement in the caster lever while locking or unlocking 9 1 The Re Load worksurface is made...

Страница 11: ...10 2 All batteries are affected by temperature The ideal storage temperature is 70 F The internal battery will gradually self discharge lose power over time especially in warm cold environments To en...

Страница 12: ...e has been blown Circuit pulled too much power Replace fuse contact PH Battery is defective Need new battery contact PH PCB defective Replace Charging hub contact PH Casters won t lock Mechanical lock...

Страница 13: ...l manual are followed This warranty is VOIDED if repairs have been made or attempted by anyone other than Palmer Hamilton and its authorized personnel If alterations have been made to the product usin...

Страница 14: ...on Street Elkhorn WI 53121 1911 Toll Free 800 788 1028 Local 262 723 8200 Fax 262 723 5180 www NomadFlexibleFurniture com To see the complete family of Palmer Hamilton products please see www palmerha...

Отзывы: