Figure 6 - Incorrect Connections

 

 

 

2.8   Rescue: 

The PALMER SAFETY 4-Person Temporary HLL is part of a complete PFAS. It is not intended as a rescue 

device. Use of this system presents a wide variety of potential rescue scenarios. Users of this system should understand 
their work environment and develop a rescue plan accordingly. It is recommended that a trained on-site rescue team be 
present during use of the system. 
 

3.0

 

System Requirements 

3.1

 

Anchorage Strength: 

End anchors selected for use with this system must have a minimum rating of 5,000 lbs. (22.2 KN) for one- and two- 

person applications & 6000lbs (26.7KN) for three-and four-person applications  

3.2

 

Structure: 

The mounting points for the anchorage must be capable of supporting no less than 5,000 lbs. (22.2 KN) for one- and two- 

person applications & 6000lbs (26.7KN) for three-and four-person applications, see Figure 7. 

 

3.2

 

Compatibility of Connectors: 

Connectors are considered to be compatible with connecting elements when they have been designed to 

work together in such a way that their sizes and shapes do not cause their gate mechanisms to inadvertently open regardless of how 
they become oriented. Contact PALMER SAFETY if you have any questions about compatibility. Connectors must be compatible with 
the anchorage or other system components. Do not use equipment that is not compatible. Non-compatible connectors may 
unintentionally disengage. Connectors must be compatible in size, shape, and strength. Self-closing, self-locking snap hooks and 
carabiners are specified by OSHA and ANSI Z359.12. 

3.3

 

Compatibility of Components: 

Equipment is designed for use with approved components and subsystems only. Substitutions or 

replacements made with non-ANSI Z359 compliant components or subsystems may jeopardize compatibility of equipment and may affect 
the safety and reliability of the complete system. Ensure compatibility between the connectors if non- PALMER SAFETY components are 
used for fall protection, see Figure 6.

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

3.4

 

Connectors: 

Only use self-locking snap hooks, rebar hooks, and carabiners with this equipment. Only use connectors that are suitable to 

each application. Ensure all connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Visually 
ensure all connectors close and lock completely. Connectors (snap hooks, rebar hooks, and carabiners) are designed for use only

 

as specified in this manual.

 

A

 

Never connect two active components (snap hooks or carabiners) to each other.

 

B

 

Never connect two active components (snap hooks or carabiners) to a single D-ring at the same time.

 

C

 

Never connect in a way that would produce a condition of loading on the gate.

 

D

 

Never attach to a object in a manner whereby the gate (of the snap hook or carabiner) would be

 

prevented from fully closing and locking. Always guard against false connections by visually inspecting for closure and lock.

 

E

 

Never attach explicitly to a constituent subcomponent (webbing, cable or rope) unless specifically provided for by the 

manufacturer’s

 instructions for 

both subcomponents (snap hook or carabiner and webbing, cable or rope).

 

F

 

Never attach in a manner where an element of the connector (gate or release lever) may become caught on the anchor thereby producing 
additional risk of false engagement.

 

G

 

Never attach a spreader snap hook to two side/positioning D-rings in a manner whereby the D-rings will engage the gates; the gates on a spreader 
must always be facing away from the D-rings during work positioning.

 

Содержание A300400

Страница 1: ...ferred to as the PALMER SAFETY 4 Person Temporary HLL the Horizontal Lifeline HLL the system or the lifeline This manual is intended to meet the Manufacturer s Instructions as required by the American...

Страница 2: ...rmediate anchor points is recommended to minimize the potential of the other workers falling IMPORTANT This product is part of a personal fall arrest restraint work positioning suspension or rescue sy...

Страница 3: ...ary in its performance depending upon the length of the system the number of workers attached and the type of PFAS being used Care should be taken to understand the capacity of the system minimum requ...

Страница 4: ...AFETY fall arrestor connecting subsystems 2 7 Clearance Requirements The PALMER SAFETY 4 Person Temporary HLL is designed to react to a fall event by elongating and deflecting to absorb energy PFAS at...

Страница 5: ...ser Capacity Each Max Two Workers 1 Find Span Length in Table Below 2 Find Freefall Distance in Table Below 3 Required Fall Clearance at the intersection of Span Length and Freefall Distance see table...

Страница 6: ...ent HLL systems for each person or shorter span lengths or intermediate anchor points is recommended to minimize the potential of the other workers falling Temporary HLL with EAL Minimum Required Fall...

Страница 7: ...bsystems only Substitutions or replacements made with non ANSI Z359 compliant components or subsystems may jeopardize compatibility of equipment and may affect the safety and reliability of the comple...

Страница 8: ...l Anchorage Connectors to be used when planning a PFAS Failure to inspect assemble install and or maintain Anchorage Connectors could result in injury or death 4 4 Connectors Deceleration Devices Conn...

Страница 9: ...tely 200 300 lbf The loose end tail length should not less than 3 3ft 1 0m Step 5 Once properly tensioned connect a PFAS system only to the connection O rings that have been preinstalled on the lifeli...

Страница 10: ...ifeline is properly tensioned Please review the inspection checklist for inspection requirements 2 Inspection Frequency Other than pre use inspection the PALMERSAFETY 4 Person Temporary HLL should be...

Страница 11: ...on results should be recorded by a competent person at least once ayear 5 Inspection Document Record inspection results on the inspection record provided below or similardocument 8 0 Labels The labels...

Страница 12: ...Inspection Record Model Serial Date ofManufacture INSPECTION DATE INSPECTOR COMMENTS PASS FAIL CORRECTIVE ACTION NEEDED APPROVED BY...

Страница 13: ...GENERAL WORK PRODUCTS LLC 6000 Je erson Hwy Harahan LA 70123...

Отзывы: