Routine maintenance

5.1   Pall filters do not normally require special attention 

except for periodic monitoring of the differential pressure 

warning device. If no such device is fitted, a specified 

scheduled time period for replacement must be 

adopted.

5.2    If external leakage is noted, replace O-ring at leak. If 

leakage persists, check sealing surfaces for scratches  

or cracks; replace any defective parts. 

5.3    Differential pressure devices actuate when the element 

needs changing or because of high fluid viscosity in 

‘cold start’ conditions. If ‘cold start’ conditions exist,  

see Section 6.2 and 6.3.

5.4    A dirty system can quickly plug a new filter element, 

especially with Pall high efficiency filter media. It may 

require one or two initial element changes to stabilize 

element life. If element life is short or differential 

pressure is excessive, filter may be undersized; refer to 

the sizing and selection section of the product literature 

or contact your local Pall representative.

5.5    Make sure replacement filter elements are stored clean  

& undamaged and that a supply of replacement 

elements is available.

Differential pressure devices

Reference should be made to product literature (M&EG410EN) 

for dimensions, operating parameters, part numbering, ordering 

information and specifications.

6.1    Differential pressure devices actuate when the element 

needs changing or because of high fluid viscosity in 

‘cold start’ conditions.

6.2    If visual indicator is fitted and actuates during ‘cold start’ 

(button changes from white to red), it will automatically 

reset when the normal operating conditions are reached. 

If indicator actuates after resetting,  

replace element.

6.3    If the electrical switch actuates (e.g. red light comes on) 

during cold start, continue operating until the signal  

(red light) goes out as system warms to normal 

operating conditions. This feature can be used as ‘warm 

up’ indication in operating procedures. If the warning 

remains or appears when system is warm, replace the 

filter element. 

All electrical pressure switches have automatic reset.

PIN 1

PIN 2

6.4    If electrical differential device is fitted the use of both 

positive indication (green light) and negative indication 

(red light for dirty element) is recommended to 

effectively monitor filter element life.

Electrical connections and ratings for “C” and “U” (normally 

closed) differential pressure switch options:

The switch is wired normally closed. Using normally closed 

configuration allows for the detection of damaged or broken 

cables or disconnection. 

All electrical pressure switches have automatic reset.

Maximum Voltage 48V DC or peak AC

Switching Current 0.5A max

 

If switch is to be connected to an inductive load or load where 

surge current or in rush current flows, then protective circuitry 

may be required to lengthen the life of the switch contacts.

G410

V E r S a l o N   H I G H   P r E S S U r E   F I l T E r S

EN

G410 Series

s e r v i c e  

i n s t r u c t i o n s

Содержание Versalon G410 Series

Страница 1: ...rom pipe work to avoid static discharge It may be necessary to allow time for the static charge to dissipate before removal Internal static discharge within a charged filter capsule may result in damage to the filter media For further information please contact Pall RECEIPT OF EQUIPMENT WARNING PLEASE CHECK THE PRODUCT LABEL PRIOR TO USE TO ENSURE PRODUCT PART NUMBERS CORRESPOND TO THE APPLICATION...

Страница 2: ...talled NOTE The G410 head is supplied if selected with one or two machined differential pressure warning ports fitted with a plastic shipping plug 4 4 Mount the filter assembly in position using four 3 8 16 UNC 2B A ports or M10 x 1 5 C ports bolts in the holes on the head mounting pads Torque bolts to 9 19 ft lb or 12 26 Nm 4 5 Use a check valve downstream of the filter if there is a possibility ...

Страница 3: ...ement needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start button changes from white to red it will automatically reset when the normal operating conditions are reached If indicator actuates after resetting replace element 6 3 If the electrical switch actuates e g red light comes on during cold start continue op...

Страница 4: ...ver 7 Filter element installation servicing During servicing the external surfaces of the filter assembly must be cleaned to remove any dust deposits Servicing must be conducted using suitable tools that do not present a hazard Servicing must also not be carried out when a potentially explosive atmosphere is present Refer to Product Datasheet TRG410TEN for item numbers for applicable replacement e...

Страница 5: ... bowl G400SKZ 1 4 Indicator If fitted See product literature 1 5 Filter element G300 series See product literature 1 Figure 2 G410 section drawing Note All product data can be found at www pall com G410 Versalon HIGH PRESSURE FILTERS EN G410 Series service instructions 1 2 5 3 4 not shown ...

Страница 6: ...ase go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid 25 Harbor Park Drive Port Washington NY 11050 1 800 289 7255 toll free US 1 516 484 3600 telephon...

Отзывы: