Specifications

Housing materials:

Head and Can:  Aluminium Alloy
Maximum operating pressure:

10 bar (150 psi)
Element burst pressure:

UE310 element 10 bard (150 psid) differential minimum
Operating temperature range:

-29°C to 120°C (-20°F to 250°F) with fluorocarbon seals for 

petroleum based and specified synthetic fluids
60°C (140°F) maximum in HWCF, water-oil emulsion or  

water glycol
Bypass valve setting options:

1.7 ± 0.2 bard (25 ± 3 psid) cracking pressure
3.4 ± 0.3 bard (50 ± 5 psid) cracking pressure
Seals:

Fluorocarbon
The actual operating conditions should be checked by the 

user to ensure that the element, housing and all seals are 

compatible with the fluid and application, and are within local 

safety codes. Please contact Pall or an approved distributor if 

further information is required.

Receipt of equipment

The filter housing, and any optional equipment, are packed 

individually for assembly by the customer. Unpack carefully 

and ensure optional items are not mislaid in packaging to be 

discarded.

General sources of information

3.1   For dimensions, operating parameters, assembly/

element part number, ordering information, notes, 

performance data and specifications refer to datasheet.

3.2   This equipment has been assessed in accordance with 

the guidelines laid down in the European Pressure 

Directive 97/23/EC and has been classified within sound 

engineering practice S.E.P. We hereby declare the 

equipment meets the requirements of article 3, section 

3, thus meeting the directive requirements. Under the 

provisions of this directive the filter assembly is suitable 

for use with group 2 fluids only.

3.3   Where under reasonably foreseeable conditions, 

including external fires, the allowable limits could be 

exceeded, suitable protective devices must be installed 

by the customer within the connecting fluid system.

Installation of housing

4.1   The filter should be installed vertically with the cover 

pointing upwards.

4.2   The minimum clearance required for element removal of 

is as follows: 

 

4.2.1 

 UT319 series: 248mm (9.8in) for length 8, 

383mm (15.1in) for length 13 and 553mm 

(21.8in) for length 20.

 

4.2.2 

The UT310 Housing is supplied without a filter  

 

 

element. For element installation and servicing  

 

 

procedures, refer to Section 7.

4.3   Threaded pressure gauges or electrical pressure 

switches, when fitted, hand tighten plus 1-2 turns with a 

wrench. Threaded differential pressure indicator, if fitted, 

must be torque tightened to 40 lbft or 54 Nm.  

If no differential pressure warning device is ordered, 

the shipping plug must be removed and replaced with 

a ‘B’ type blanking plug (HA9000-A104Z) and torque 

tightened to 40 lbft /54 Nm. 

NOTE: Never place the port plug in this port without first 

installing uniform size -014 O-ring in lower O-ring groove, 

otherwise a small bypass flow will result, allowing contaminant 

downstream of the filter element.
NOTE: The UT310 housing is supplied with a machined 

pressure gauge/switch ports fitted with blanking plug.

4.4   Mount the filter assembly in position using four bolts in 

the holes on the head mounting pads. Torque bolts to 

16-20 lbft (22-27 Nm).

4.5   Install the filter housing using additional piping/valving to 

allow complete filter assembly bypass if filter maintenance 

is required without system shutdown. This series is not 

available in a duplex or service bypass configuration.

NOTE: Piping supports should be provided as close as is 

practicable to the port connections in order to minimize 

external loads. This filter assembly must not be electronically 

isolated from the user’s earthing system. This filter assembly 

must be earthed by connecting the user’s earthing system to 

one of the inlet/outlet connections.

4.6   Connect lines or hoses to housing inlet ports.
Note: Painting of the filter housing is optional. The coating 

on the filter housing is a suitable painting base. Cover the 

pressure warning device and nameplate if painting of the 

housing takes place.

CAUTION: 

Maximum surge flow should not exceed 1.3 times 

normal flow.

WARNING:

USE FITTINGS OR ADAPTORS COMPATIBLE WITH 

PORTS SUPPLIED AS SHOWN BY PART NUMBER 

ON NAMEPLATE AND NOTED IN DATA SHEETS: 

USE OF INCORRECT FITTINGS OR ADAPTORS CAN 

CAUSE FILTER HOUSING OR MANIFOLD FAILURE 

RESULTING IN LOSS OF PRESSURE AND POSSIBLE 

SYSTEM FAILURE OR PERSONAL INJURY.

CAUTION:

Reverse flow through filter element will cause damage.

CAUTION:

Never operate the filter unless all warning device ports 

are sealed. 

UT310

UT310 Series

RETURN  LINE  IN-TANK  FILTERS

s e r v i c e  

i n s t r u c t i o n s

Содержание UT310 Series

Страница 1: ...e necessary to allow time for the static charge to dissipate before removal Internal static discharge within a charged filter capsule may result in damage to the filter media For further information p...

Страница 2: ...without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded pressure gauges or electrical pressure switches when fitted hand tighten plus 1 2 turns with...

Страница 3: ...ss Switches are pre set 1 1 bar 16 psi or 2 4 bar 35 psi depending on bypass valve setting Maximum system pressure 10 bar 150 psi Electrical differential pressure switch operation When preset differen...

Страница 4: ...Seller does not warrant the service life of the filter element as this is beyond the Seller s control and depends upon the condition of the system into which the filter is installed Seller s liability...

Страница 5: ...NGLISH 5 9 Parts List List Description Quantity 1 Head 1 2 Cover sub assembly Fluorocarbon 1 3 Can sub assembly 1 4 Indicator options 3 Gauge or Pressure switch 5 O ring cover to head 1 6 O ring isola...

Страница 6: ...6 Figure 2 UT310 UT310 Series RETURN LINE IN TANK FILTERS service instructions Not shown...

Страница 7: ...aladros pasantes roscados Profundidad AA 4 t yskierteist reik syvyys AA 4 trous taraud s de profondeur AA 4 fori completamente filettati profondit AA 4 tapgaten met draad over volle diepte 4st f sth l...

Страница 8: ...the world For Pall representatives in your area please go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and pr...

Отзывы: