UR229

UR229 Series

D U P L E X   F I L T E R   A S S E M B L Y

s e r v i c e  

i n s t r u c t i o n s

3

(d) 

Jog system and fill filter until all air bleeds through the  

 

plug, then tighten plug. Pressurize system fully and  

 

check for leaks; if leaks occur shut down, depressurize,  

 

and repair leak before proceeding. Refer to section 5.2.

(e) 

Depressurize the system.

(f)  

Open right hand bleed plug a minimum of one and one  

 

half turns.

(g)   Position change-over valve to allow flow through right  

 

hand housing. Jog system and fill filter until all air bleeds  

 

through the plug, then tighten plug.

(h)   Fully pressurize and check for leaks, if leaks occur shut  

 

down, depressurize, and repair leak before proceeding.  

 

Refer to section 5.2.

(i)  

On completion of commissioning, position change-over  

 

valve to select on-line side of housing.

Routine maintenance

5.1  

Pall

 filters do not normally require special attention 

except for periodic monitoring of the differential pressure 

warning device. Schedule replacement of filter element 

every six months or sooner, and have ample supply of 

spare elements available. 

5.2   If external leakage is noted, replace O-ring at leak. If 

leakage persists, check sealing surfaces for scratches or 

cracks; replace any defective parts. 

5.3   Differential pressure devices actuate when the element 

needs changing or because of high fluid viscosity in 

‘cold start’ conditions. If ‘cold start’ conditions exist, see 

Section 6.2 and 6.3.

5.4   A dirty system can quickly plug a new filter element, 

especially with 

Pall

 high efficiency filter media. It may 

require one or two initial element changes to stabilize 

element life. If element life is short or differential 

pressure is excessive, filter may be undersized; refer to 

the sizing and selection section of the product literature 

or contact your local Pall representative.

Differential pressure devices (optional)

Reference should be made to product literature for dimensions, 

operating parameters, part numbering, ordering information 

and specifications. 
6.1   Differential pressure devices actuate when the element 

needs changing or because of high fluid viscosity in 

‘cold start’ conditions. 

6.2  If a visual indicator is fitted and actuates during ‘cold  

 

start’ (red button extends 5mm, 3/16”), reset by   

 

depressing the button when the normal operating  

 

temperature is reached. If indicator actuates after  

 

resetting at normal operating temperature, replace  

 

the element

NOTE: Option ‘P’ visual indicator has thermal lockout  

and manual reset. No signal below 0°C (32°F), signal  

above 29°C (80°F

).

6.3  If the electrical switch actuates (e.g. red light comes on)  

 

during cold start, continue operating until the signal (red  

 

light) goes out as system warms to normal operating  

 

temperature. This feature can be used as ‘warm up’  

 

indication in operating procedures. If the warning signal  

 

(red light) remains or appears when system is warm,  

 

replace the filter element.

ENGLISH

6.4   Use of both positive indication (green light) and negative 

indication (red light for dirty element) is recommended to 

effectively monitor filter element life.

Electrical connections and ratings for all differential 

pressure switch options:

110 VAC 

 4A (inductive), 

4A (resistive)

220 VAC 

 4A (inductive), 

4A (resistive)

28 VDC 

 3A (inductive), 

5A (resistive)

48 VDC 

 1A (inductive), 

1.5A (resistive)

125 VDC 

 0.25A (inductive), 

0.5A (resistive)

Maximum inrush - 24 amps.
Underwriter’s lab. Inc. listed ratings of pressure switch 

(Microswitch) options are:
4 amps at 250 VAC
0.25 amp resistive at 220 VDC
0.50 amp resistive at 110 VDC

Electrical differential pressure switch operation:

When preset differential pressure is exceeded continuity 

switches from ‘C’ - ‘A’ to ‘C’ - ‘B’.
When differential pressure decreases below the pre-set value 

continuity returns to ‘C’ - ‘A’.

Filter element servicing

During servicing the external surfaces of the filter assembly 

must be cleaned to remove any dust deposits. Servicing 

must be conducted using suitable tools that do not present 

a hazard. Do not service when a potentially explosive 

atmosphere is present.

Refer to Pall Product Literature for item numbers for applicable 

replacement element series. Remove and replace element as
follows:

CAUTION:

Failure to bleed the filter housing adequately will 

increase the dissolved air content of the system fluid 

which will shorten fluid life and may cause other

problems in the system.

Figure 1 

- Switch Circuit Diagram

CAUTION:

Filter elements should be replaced upon indication or 

at specified intervals, six months maximum. Failure to 

change the element will cause the filter to go into bypass.

WARNING:

FAILURE TO DEPRESSURISE THE FILTER BEFORE 

SERVICING ELEMENT COULD RESULT IN EXPLOSIVE 

LOSS OF FLUID, DAMAGE TO EQUIPMENT AND

POSSIBLE PERSONAL INJURY.

C

or black

or tag 2

A

or white

or tag 1 

B

or red 

or tag 3 

LOW DIFFERENTIAL PRESSURE

HIGH DIFFERENTIAL PRESSURE

Содержание UR229 Series

Страница 1: ... ENSURE PRODUCT PART NUMBERS CORRESPOND TO THE APPLICATION a Unpack carefully and check items against invoice b Store the filter capsule assembly in clean dry conditions between 0 C and 30 C 32 F and 86 F without exposure to irradiation sources like direct sunlight and wherever practical in the packaging as delivered Ensure that pre wet capsules are stored above 0 C 32 F to avoid freezing c DO NOT...

Страница 2: ...wards for UR229C version and downwards for UR229H version 4 2 The minimum clearance required for element removal of is as follows 4 2 1 UR229C series cover service 429mm 16 9in for length 08 563mm 22 2in for length 13 734mm 28 9in for length 20 and 1242mm 48 9in for length 40 4 3 Threaded differential pressure devices when fitted must be torque tightened to 40 43 ft lb or 54 58 Nm All visual indic...

Страница 3: ...indicator actuates after resetting at normal operating temperature replace the element NOTE Option P visual indicator has thermal lockout and manual reset No signal below 0 C 32 F signal above 29 C 80 F 6 3 If the electrical switch actuates e g red light comes on during cold start continue operating until the signal red light goes out as system warms to normal operating temperature This feature ca...

Страница 4: ...uter valve 2 when a bubble free stream of oil flows from the bleed plug Tighten the bleed plug 7 2 Pull the latching pin and rotate change over valve handle 7 180 to bring off line housing on line Insert latching pin to prevent accidental handle movement NOTE Pointed end of change over valve handle 7 indicates the filter housing on line 7 3 The off line housing is now isolated from the system by t...

Страница 5: ... point toward the center of the Check Valve Assembly see Fig 2 9 6 Replace O rings and U cup seals Use appropriate kit per type of seal See Check Valve Seal Kit list Section 13 NOTE Poppets and seats are matched sets Do not interchange seats and poppets See Fig 3 for proper part configuration 9 7 Assemble per Figure 3 NOTE Use seal installation tool to install new seals and poppets onto the valve ...

Страница 6: ...signated by Seller All claims must be accompanied by full particulars including system operating conditions if applicable Seller shall not be liable for any product altered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor s...

Страница 7: ...41 Lg 1 16 O Ring 033 1 17 Seat Ball Valve 2 18 O Ring 130 2 19 Ball MC 1 20 O Ring 134 2 8 21 O Ring 029 2 22 Seat Valve 2 23 Poppet 2 24 Seal U Cup 2 25 Shaft Valve 1 26 Spring Compression 1 27 Installation Tool U Cup 1 UR229 UR229 Series 12 Filter Assembly Seal Kit List Item Description Catalog Number Quantity 1 Nitrile 1386269 1 2 Fluorocarbon 1386270 1 3 Ethylene Propylene 1386271 1 13 Ball V...

Страница 8: ...DUPLEX FILTER ASSEMBLY service instructions 8 UR229 UR229 Series Figure 4 UR229 7 Handle 8 Drain Plug 5 Bleed Plug 4 Cover 3 Tube 6A Bolt Hex 1 Head 6 Socket Head Cap Screw ...

Страница 9: ...DUPLEX FILTER ASSEMBLY service instructions ENGLISH 9 UR229C UR229H UR229C UR229H Series 8 Drain Plug 8 Drain Plug ...

Страница 10: ...DUPLEX FILTER ASSEMBLY service instructions 10 UR229C UR229H UR229C UR229H Series Figure 6 10 Filter Element 12 Ball Valve 11 Check Valve ...

Страница 11: ...1 19 Ball 17 Ball Seat 15 Nylon Locking Nub 13 1 O Ring 134 13 O Ring 147 22 21 14 Retainer 23 16 O Ring 033 24 15 Exploded view of Nylon Bar locking nub 26 Spring 21 O Ring 029 23 Poppet 22 Valve Seat 27 U Cup Installation Tool 28 Valve Shaft 29 O Ring 116 30 Teflon Washer 25 Shaft 24 U Cup Seal ...

Страница 12: ...nd procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid Copyright 2018 Pall Corporation Pall and are trademarks of Pall Corporation Indicates a trademark registered in the USA Better Lives Better Planet and Filtration Separation Solution SM are service marks of Pall Corporation Pall Machinery and...

Отзывы: