4.8 

Jog system and fill filter. Pressurize system fully and 
check for leaks; if leaks occur refer to Section 5.

5

Routine maintenance

5.1

Pall

filters do not normally require special attention

except for periodic monitoring of the differential pressure
warning device. Schedule replacement of filter element
every six months or sooner, and have ample supply of
spare elements available.

5.2

If external leakage is noted, replace O-ring at leak. If
leakage persists, check sealing surfaces for scratches or
cracks; replace any defective parts.

5.3

Differential pressure devices actuate when the element
needs changing or because of high fluid viscosity in
'cold start' conditions. If 'cold start' conditions exist, see
Section 6.2 and 6.3.

5.4

A dirty system can quickly plug a new filter element,
especially with Pall high efficiency filter media. It may
require one or two initial element changes to stabilize
element life. If element life is short or differential
pressure is excessive, filter may be undersized; refer to
the sizing and selection section of the product literature
or contact your local Pall representative.

5.5

Make sure element change labels are clean and
undamaged. Replace illegible labels with the appropriate
new labels.

6

Differential Pressure Devices

Reference should be made to product literature for dimensions,
operating parameters, part numbering, ordering information
and specifications.
6.1

Differential pressure devices actuate when the element
needs changing or because of high fluid viscosity in
'cold start' conditions.

6.2

If the differential pressure switch actuates during cold 
start, continue operating until the signal goes out as 
system warms to normal operating temperature. This 
feature can be used as 'warm up' indication in operating
procedures. If the warning signal remains or appears
when system is warm, replace the filter element.

6.3

Use of both positive indication and negative indication is
recommended to effectively monitor filter element life.

NOTE: These electrical and visual Differential pressure 
devices (respectively, F5 and FD series) are very specific 
to the UR209 series.  

Electrical connections and ratings for F5 code electrical
pressure switch options:

28 VDC 

=  3A (inductive),

5A (resistive)

Amperage: 200mA 

maximum

Circuit:

SPST Normally open circuit
Ground through filter assembly 
to chassis

CAUTION:
Failure to bleed the filter housing adequately will
increase the dissolved air content of the system fluid
which will shorten fluid life and may cause other
problems in the system.

UR209

UR209 Series

R E T U R N   L I N E   F I LT E R S

s e r v i c e  

i n s t r u c t i o n s

2

Figure 1 

- Switch Circuit Diagram

Содержание UR209 Series

Страница 1: ...service instructions UR209 UR209 Series 1372872 IM SI UR209 EN UR209 Service Instructions ENGLISH ...

Страница 2: ...ease of servicing it is recommended that it be installed vertically with the filter bowl pointing downwards 4 2 The minimum clearance required for element removal is 69 mm 2 7 for all lengths 4 3 The UR209 series housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 NOTE The UR209 head is supplied with one machined differential pressure w...

Страница 3: ...appropriate new labels 6 Differential Pressure Devices Reference should be made to product literature for dimensions operating parameters part numbering ordering information and specifications 6 1 Differential pressure devices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If the differential pressure switch actuates during cold start contin...

Страница 4: ...he system and check for leaks as per section 4 8 7 8 After element change ENSURE VISUAL INDICATOR IS RESET BY PUSHING IN THE RED BUTTON Electrical differential pressure devices will reset automatically When system reaches normal operating temperature check that the switch has not actuated and or the visual warning button has remained depressed If visual indicator rises due to a cold start conditio...

Страница 5: ...utor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in use storage transportation or handling In no event will Seller be liable for any damage...

Страница 6: ...UR209 UR209 Series s e r v i c e instructions 5 2 4 5 Figure 1 Refer to product literature 3 1 Not shown on this diagram Inlet RETURN LINE FILTERS ...

Страница 7: ...UR209 UR209 Series s e r v i c e instructions 6 RETURN LINE FILTERS ...

Страница 8: ...nd IMSIUR209 Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan Thailand United Arab E...

Отзывы: