Assemble System 

Installation 

1.   Verify all components have been provided. (See  

Tray Assembly and Fittings/Part Bag figures on  

reverse side)

2.   Cut PharMed tubing (yellow) to lengths as specified  

(See page 3)

3.   Slide tube clamps onto tubing and insert fittings into 

tubing as shown on back page. Slide clamps over  

fitting ends and pinch together (use pliers if  

necessary to assist)

4.   Lay drip tray on work counter. (Note: if there is any 

rocking of tray, the bottom feet can be adjusted by 

rotating as necessary as shown in figure 1)

5.   Slide stir plate into left compartment of drip tray  

underneath reservoir bracket. Attach capsule stand on 

raised boss in center of drip tray with screw in threaded 

hole. Turn screw until snug fit, but allows the stand to 

move. (See figure 2)

6.   Connect 3-way valves to fittings on reservoir outlet  

and inlet. Attach male luer plugs onto female luer  

connectors on 3-way valves. (See figure 3)

7.   Place reservoir onto stir plate with outlet toward rear  

of plate. (See figure 4)

 8.   Connect “long tube” to 3-way valve at reservoir outlet 

and to fitting on rear gauge mount. (See figure 4)

9.    Attach pump head onto pump with supplied screws.

(See figure 5)

Figure 2

Figure 3 

Figure 4

Figure 1 

Stir plate

Capsule  

stand

3-Way valve  

on inlet

3-Way valve  

on outlet

Male luer  

pugs

 

Long tube

Reservoir 

3-way 

valve  

Pump

Pump 

head

Mounting 

screws 

Figure 5

Содержание Minimate EVO TFF

Страница 1: ...s Information Part No Description 97008 Minimate EVO TFF Reservoir Kit System includes Reservoir 500 mL with fittings Lid with fittings and o ring 97009 Minimate EVO TFF Drip Tray Kit System includes Drip Tray with reservoir and filter capsule brackets Pressure gages 2 with mounts and fittings Minimate Capsule stand 97010 Minimate EVO TFF Stir Plate Kit System includes VWR Stir Plate Power adapter...

Страница 2: ...ay underneath reservoir bracket Attach capsule stand on raised boss in center of drip tray with screw in threaded hole Turn screw until snug fit but allows the stand to move See figure 2 6 Connect 3 way valves to fittings on reservoir outlet and inlet Attach male luer plugs onto female luer connectors on 3 way valves See figure 3 7 Place reservoir onto stir plate with outlet toward rear of plate S...

Страница 3: ...drain the system by running the water to a waste container instead of the reservoir open the pump head examine the tubing to make sure it is not damaged and re insert e Close the pump head and continue with the flushing procedure 12 Attach male luer coupler to fitting on front of gauge mount Attach Minimate Capsule feed port to coupler rotate capsule to left into capsule stand and onto capsule bra...

Страница 4: ...ing clamp and female luer 1 8 hose barb to tube Connect fitting to filtrate port and place open tube end into filtrate receiver vessel See figure 8 16 If performing diafiltration place lid onto reservoir Connect 1 way valves onto fittings on top of reservoir From the Minimate Capsule filter packaging cut a length of tubing to reach from 1 way valve on reservoir lid top to diafiltration vessel Atta...

Отзывы: