background image

27

12

Appendix 4 - Spares and Consumables

  Name

Starter Pack

Replacement 

  

(50 tests)

Pack (250 tests) 

  Total Alkalinity (Alkaphot

®

)

PM 188

AP 188 

  Aluminium

PM 166

AP 166 

  Ammonia

PM 152

AP 152 

  Bromine

PM 060

AP 060 

  Calcium Hardness (Calcicol™)

PM 252

AP 252 

  Chloride/Salt (Chloridol™)

PM 268

AP 268 

  Chlorine - Free (DPD 1)

PM 011

AP 011 

  Chlorine - Free, extended range (DPD XF)

PM 013

AP 013 

  Chlorine - Free, Combined and Total (DPD 1 and DPD 3)

PM 031

AP 031 

  Chlorine - Free, Combined and Total, extended range (DPD XF and DPD XT)

PM 033

AP 033 

  Chlorine - Total (DPD 4)

PM 041

AP 041 

  Chlorine - Total (DPD 3 only)

-

AP 031/1 

  Chlorine - Total, extended range (DPD XT only)

-

AP 033/1 

  Chlorine HR

PM 162

AP 162 

  Copper - Free, Combined and Total (Coppercol

®

)

PM 186

AP 186 

  Copper - Free

-

AP 187 

  Cyanuric Acid

PM 087

AP 087 

  Hardness - Total (Hardicol

®

)

PM 254

AP 254 

  Hydrogen Peroxide HR

PM 105

AP 105 

  Iron LR

-

AP 155 

  Manganese HR

PM 174

AP 174 

  Nitrate (Nitratest™) 

PM 163

AP 163 (200 tests) 

  Ozone (DPD method)

PM 056

AP 156 

  pH - Phenol Red

PM 130

AP 130 

  PHMB

PM 272

AP 272 

  Phosphate LR

PM 177

AP 177 (200 tests) 

  Sulphate

PM 154

AP 154

Reagents

  DPD Glycine, 250 pack

AT 056 

  EDTA Tablets, 250 pack

AT 090 

  DPD Oxystop, 250 pack

AP 017

Accessory Reagents

  

PT 804 Pooltest 25 Check Standards

Validation standards for Pooltest 25 with certificate. 
Supplied in hard transport/storage case 

  

S06232

Pooltest 25 Professional Series Service and Calibration

Check Standards/Service for Pooltest 25 

  

PT 595/5 Photometer Cuvettes

Pack of 5 glass cuvettes with caps. 20mm OD, 77mm tall with 10ml 
graduation. For Pooltest 25 and Pooltest 9  

  

PT 501 Cuvette Rack

Rack for PT 595. Holds 8 cuvettes 

  

PT 502 Crush/Stirring Rods

Pack of 10 crush/stirring rods 

  

PT 663 Cuvette Brush

For cleaning cuvettes, length 120mm 

  

PT 500 De-ion Pack

Cuvettes and Racks

Содержание Pooltest 25

Страница 1: ...Pooltest 25 Operation Manual ZI INST 7025B EN...

Страница 2: ...Tips Troubleshooting Technical Specifications Spares and Consumables Pocket Sensor for TDS Engineer s Kit Only 6 Introduction 3 Quick Start 4 1 2 Chapter Page Chapter Page 3 Taking a Sample 5 4 Starti...

Страница 3: ...ues produce small particles to scatter the source beam the amount of scatter providing a result for the concentration of parameter under test The Pooltest 25 is provided with programmed methods for a...

Страница 4: ...acklight with the screen separated into four clear easy to read zones 1 Mode or Test Identification 2 Dialogue screen prompts and choices will be displayed as a list Select using up down arrows 3 Info...

Страница 5: ...ntre of the pool and at least 20cm below the surface of the water Rinse any sample container repeatedly with the sample to prevent any cross contamination from previous samples Once collected the samp...

Страница 6: ...install a complete set of new batteries observing the correct polarity as indicated Use 3 x 1 5V AA alkaline batteries or equivalent See Appendix 2 for more details To avoid corrosion damage through l...

Страница 7: ...t recent result shown by default Scroll through results using the up down arrows Select Back to return to the previous menu Clear the entire log can be deleted from the Pooltest 25 if the instrument i...

Страница 8: ...ght the ID and select Edit Choose either Edit to modify the existing entry or Delete to remove it from the list 5 3 Sample ID The Pooltest 25 offers the option to create up to 24 unique alphanumeric S...

Страница 9: ...ars as a removable hard drive when connected to a PC in Hard Disk mode Upon connection the remote drive will have the following files included Pooltest 25_ afx where represent version numbers of softw...

Страница 10: ...ns The default code is set to 6812 To change the System Lock code follow the on screen prompts to choose a memorable four digit number When the System Lock is applied the items accessible within the S...

Страница 11: ...Back Light The instrument display features a high intensity backlight to support use in low light conditions The backlight is designed to use minimal energy but activating will naturally consume batte...

Страница 12: ...ypad to directly access the 10 most common tests with a single key push Choose a Test the full list of test parameters is available by selecting Choose a Test and scrolling using the up down keys When...

Страница 13: ...rary memory of the Pooltest 25 and will be used for all subsequent tests until The instrument is powered down temporary memory is lost deleted A new Blank reading is taken this option is available on...

Страница 14: ...t down the reaction time required While in the Insert sample screen use the right key to move the cursor to highlight Timer The programmed reaction time will be displayed Press OK to Start the countdo...

Страница 15: ...ethods that can be applied known as Follow on Tests e g Phot 008 Total Chlorine follows Phot 007 Free Chlorine Follow on methods are usually either based on further reagent addition to the sample just...

Страница 16: ...Stand for one minute before proceeding This will prevent a false response caused by the shock treatment chemicals 2 Add one DPD 3 or DPD XT tablet crush and mix to dissolve 3 Stand for two minutes to...

Страница 17: ...he DPD Glycine complexes ozone in the sample and the result displayed equates to chlorine or bromine present in the sample only 4 Subtract the result obtained in Step 3 from the initial result to dete...

Страница 18: ...ange Colourless Purple 1 Fill test cuvette with sample to the 10ml mark 2 Add one Coppercol No 1 tablet crush and mix to dissolve 3 Take photometer reading Test 12 Copper Total 5 Range 0 5 00mg l ppm...

Страница 19: ...sh and mix fully to dissolve 4 Stand for five minutes 5 Take photometer reading Test 18 Nitrate Range 0 100mg l ppm No3 Colour change Colourless Red 1 Take a clean Nitratest Tube PT 526 Using the Meas...

Страница 20: ...checking hydrogen peroxide levels in pools treated with PHMB Test 31 32 33 Chlorine Free 5 Monochloramine and Dichloramine Range 0 5 00mg l ppm Cl2 Colour change Colourless purple red Free Chlorine in...

Страница 21: ...d as follows 1 Select Test 77 by pressing the Alkalinity key no 7 twice or from the Choose a Test list 2 Carry out the Alkalinity test then select Follow On from the results screen 3 Carry out the Cal...

Страница 22: ...Check Standard Mode and press OK Two choices are offered Enter Check use the up down keys to Standard Values adjust the displayed values to match the certificate Check Standard insert the Check Stand...

Страница 23: ...s or if the solids are settleable and will not lie in the optical path allowing them to settle in the photometer cuvette can be acceptable 5 Calibration curves relate transmission absorbance to concen...

Страница 24: ...ers may fail the Check Standard validation step due to the requirement for service calibration Contact your local Palintest partner for service and support Ensure the Check Standards are inserted corr...

Страница 25: ...ed for cleaning of the optical chamber changing batteries and validating performance using the Check Standard Mode Cleaning the Optical Chamber The optical chamber has been designed to support removal...

Страница 26: ...mA delivered via USB port Power Management Auto switch off user selectable between 5 15 minutes on battery or continuous operation Power Saving User control for Backlight to minimise battery consumpti...

Страница 27: ...tal Hardicol PM 254 AP 254 Hydrogen Peroxide HR PM 105 AP 105 Iron LR AP 155 Manganese HR PM 174 AP 174 Nitrate Nitratest PM 163 AP 163 200 tests Ozone DPD method PM 056 AP 156 pH Phenol Red PM 130 AP...

Страница 28: ...reading and the lower display sequentially shows calibration standard values 84 uS 1413 uS 12 88 mS if the measuring range of the tester is set to AUTO 4 Rinse the electrode with the calibration stand...

Страница 29: ...asurement for temperature Celsius or Fahrenheit Dip the tester into a solution of known temperature and allow time for the temperature reading to stabilise 2 Press INC or DEC key to bring the tester t...

Страница 30: ...www palintest com...

Отзывы: