MiniFix 1100/1320
Owner’s Manual
Rev. 1.3
- 21 -
9.3
Checking and Changing Oil
Check the quality of hydraulic fluid. If bad, take the following steps to change the oil.
Checking Oil:
1. Lower gate to ground and tilt platform down. Open the power pack, so you can reach the oil filler cap.
Wires will be connected to the motor so remove the cover slowly.
Changing Oil:
2. Unscrew the oil drainage bolt (bottom of tray) and let the fluid drain out of the reservoir into an approved
container.
If the reservoir is empty fill it up with recommended hydraulic oil, as shown on 8.3.1. The oil level must be
within the marked limits at the oil tank or dipstick (see indication at oil tank or dipstick).
After filling, the liftgate must be opened and the oil level topped up if necessary.
Motor
Cover
Reservoir
Check and refill oil.
Drain Oil
Cover
Latches
Cap
9.3.1
Recommended Hydraulic Fluids
TEMP. RANGE
BRAND
-10 TO 150 F
EXXON
UNIVIS J26
MOBIL OIL
DTE 13M
CHEVRON
AW MV32
ROSEMEAD
MV 150 (32)
-50 TO 150 F
MOBIL
DTE 13M
SHELL
AERO FLUID 4
EXTREME COLD TEMPERATURE:
USE MILITARY SPEC:
MIL H5606