7 Electrical Installation
Revision 1.5
- 23 -
Electrical Installation
7
When performing electrical installation, be certain to install and secure everything in a way where it is not
subject to damage from moving parts, sharp edges, exhaust systems, etc.
•
ANY deviation from PALFINGER Liftgates’
recommended power setup (see 7 Electrical
Installation)
will
void warranty and product liability
unless
you have a written confirmation by PALFINGER
Liftgates that allows you to do specific changes.
•
Never tie the power cables to gas or diesel lines on trucks – it is a fire hazard.
•
Never exceed rating of existing fuses located at the battery, control board and/or the pump and
motor which may result in serious damage to the equipment.
•
Never jump the 150 Amp circuit breaker at the batteries unless otherwise instructed by the
PALFINGER Liftgates
technical support center
•
Assure all connections are tight and securely fastened
•
Heat shrink any connection to all cables.
•
Never secure a cable in a way where it can make contact with other wiring, brake-, fuel- or air-
lines etc. or get pinched against other objects.
7.1
Breaker Installation
•
Mount circuit breaker securely in battery box or at positive battery post using supplied buss bar
•
Connect liftgate 2Ga. cable to open stud on circuit breaker
•
Connect 2Ga. jumper from open stud on breaker to positive battery post if circuit breaker was not
mounted straight at battery with buss bar
150 AMP
Resetable Breaker
R
E
SE
T
Figure 19 Circuit breaker installation
Connect 2 Ga cable
coming from lift gate
Connect here
to Positive
Battery post