![PALDU 1100-12 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/paldu/1100-12/1100-12_operating-instructions-manual_747899024.webp)
Maintenance
Before maintenance work on the machine, it is vital to switch off the drive and secure it so
it cannot be switched on accidentally or started-up by unauthorised persons.
Disconnect the machine from the mains.
▪ In addition, pull out the plug of the device.
▪ Disengage the universal joint shaft on the tractor.
– Before disengaging, turn the manual throttle to minimum.
▪ Remove the universal joint shaft from the tractor.
Work on electrical equipment must only be carried out by qualified electricians.
Never work without the protective guards in place.
Only use original - Paldu - spare parts.
Tool guide
1
2
1
Grease nipple
2
Grease brush
Lubricate the grease nipple on the tool guide with lubricating grease every 10 hours.
Apply grease with a brush.
The tool guide must always be well greased.
Recommended lubricating greases:
Manufacturer
Type
Genol
Multi-purpose grease
Fuchs
Multi-purpose grease 5028
Oil changing
Old oil must be disposed of in an environment-friendly manner. Find out about the
environmental regulations in your country.
Changing the hydraulic oil
The first oil change should be carried out after 500 operating hours, all further oil changes
should then be carried out after every 1000 operating hours or annually.
▪ Retract the splitting blade before changing the oil.
▪ Remove the ventilation screw.
9
9.1
9.2
9.2.1
Maintenance
24
Содержание 1100-12
Страница 35: ......