Pag.: 57/60
Cod. 004770370
TC120
4.7 System’s plan No. 7
Functioning
:
In case of request of hot sanitary water (with temperature more than
A05),
The 3 outputs pump works to satisfy the necessity.
Led functioning:
When the pump is activated to the distribution system the led
PUMP works
When the pump is activated to the sanitary system the led
AUX works
Used IN/OUT
SERIGRAPHY
CONNECTORS
System’s symbol
Probe2
Probe2
17 – 18
S2
FlowSwitch
FLUX
19 – 20
FLUX
3 outputs pump
AUX
7 BLUE
6 BLACK
8 BROWN
P3
INSTALLER’S MENU PARAMETERS’ SET (Par. 3.5)
Parameter
Description
U.
Min Default
Max
C- -
System’s configuration
n
C01
C07
C08
A10
Alarm thermostat
°C
60
85
90
P01
Probe’s type: ‘
0’ =10K blue; ‘1’ 100K grey
n
0
0
1
P02
Activation output’s AUX (6-7) protection functions
n
0
0
1
To activate the protection functions: anti freezing function and anti block program, activate the installer’s parameter P02 in
the installer’s menu
Parameters USER’S MENU (Par. 5.0)
Parameter
Description
U.
Min Default
Max
A04
Starting threshold 3 outputs pump
°C
50
60
80
A05
Changing rotation threshold 3 outputs pump
°C
50
55
80
I04
Thermostat hysteresis parameter
A04
°K
0
2
5
I05
Thermostat hysteresis parameter
A05
°K
0
2
5
PLAN No. 7
TERMOPALEX WITH KIT ANTICONDENSATE
AND SANITARY EXCHANGER
C1: controller
S2
P3
E1
FLUX
F
CONFIGURATION
C07
D
distribution
system
FlowSwitch
Heating
Exchanger
HSo
Sanitary hot
water
HSi
Sanitary cold
water
1 2 3 4 5 6 7 8 9 10 11 12 13 14
20 19 18 17 16 15
N
L
-O
N
L
-O
FF