70
004778890 - 12/11/2021
dispersion.
When the fireplace is used to heat two
or more adjacent rooms, it is essential
to promote the recirculation of ambient
air to even out the temperature in the
different rooms, therefore provide the
doors with grilles or keep them ajar.
Double duct
Fig. 39
Single duct
Fig. 40
7.6 Creating technical holes on the
cladding
The cladding must only be done by qualified
personnel.
Technical holes must be made on the cladding
and on the hood for:
1)
the display housing;
2)
the air vents;
3)
the heat exhaust ventilation in the hood;
4)
the ventilation of the cladding on the base;
5)
pellet loading opening.
The holes must comply with the measurements
indicated in the figure:
115
65
295
295
295
295
4
1
2
3
5
1
Fig. 41
7.7 Electrical connection
Simply connect the appliance to the electrical
system using the supplied plug (
Fig. 42
).
The electrical connection (plug) must be easily
accessible after appliance installation as well.
If the power supply cable is damaged
it must be replaced by the technical
assistance service or a qualified techni-