ENGLISH
6.5.1 Discharge through roof using a traditional chimney
The
chimney
used
to
discharge
the
À
ue gas must
be made in accordance with standards UNI 10683
- EN 1856-1-2 - EN 1857 - EN 1443 - EN 13384-
1-3 - EN 12391-1 both as regards the dimensions
and the construction materials used.
DAMAGED chimneys made from unsuitable
material (asbestos cement, galvanised steel,
etc.... with a rough and porous inside surface) are
prohibited by law and affect proper stove operation.
The
À
ue gas can be discharged through a traditional
chimney (Fig. 5.8) as long as you make sure on the
state of maintenance of the chimney.
For larger chimneys, suitably insulated steel
pipes need to be inserted on the inside (diameter
according to the length) (Fig. 5.9).
Makes sure connections to brick chimneys are
suitably sealed.
If
the
À
ues run through wooden roofs or walls,
special certi
¿
ed pass-through kits need to be used,
available on the market.
A) Chimney pot with wind protection
B) Seal
C) Inspection
1) Vermiculite and/or rock wool.
2) Steel
pipes.
3) Closure
panel.
29
COD. 00477 7260 - 09/2018 - Palazzetti - PN - Italy
Fig. 5.8
Fig. 5.9
1
2
3