background image

ZENIT 

80

+

 

TYPE TUBE RADIANT HEATER 

User’s Manual

11

The minimal mounting height

10

15

20

25

30

35

40

45

50

55

60

Vízszintes

3,4

3,7

4

4,2

4,4

4,6

4,9

5,2

5,4

5,7

5,9

30

o

3

3,2

3,4

3,7

3,9

4,1

4,3

4,6

4,8

5

5,3

Vízszintes

3,2

3,5

3,7

4

4,2

4,5

4,7

5

5,2

5,4

5,6

30

o

2,7

3

3,2

3,4

3,6

3,9

4,1

4,3

4,5

4,7

4,9

ZENIT

„U” alakú

Egyenes

„E”

Típus

Kivitel

Szerelés

Bevitt teljesítmény (kW), beépítési magasság (m)

„U” 

FORM

„I” FORM

Type

Execution Location

horizontal

horizontal

Input (kW) mounting height (m)

Minimal ascent of installation

23.picture Minimal ascent of installation

Suspension

After determining the number and exact position of appliances and hangers,you have to provide for hanging them at a minimum of 400 

mm (hanging chains for example). This is necessary, so it does not hinder the length change, which increases dueing thermal expansion,-

hereby appliances does not deform.Install hangers under the roof structure, under buttresses or scaffolding among columns or nerby 

wall.The suspension of appliances have to be executed by hanger located on the fan side of burner and combination brackets.

At mounting take the correct hanging up of burner head into consideration  becuse the improper hanging up can cause deformation on 

the burner head during heat dilatation.

Maximal angle at a complete appliance: (max.30°)

Example for location of suspensions

9.picture: Minimal installation height

Содержание ZENIT 80+ Series

Страница 1: ...EN User s Manual www pakole com 009_007_011_180712_V001_EN PROPANE OR NATURAL GAS FIRED ZENIT TYPE TUBE RADIANT HEATER Appliance types ZENIT 80 12 42 Linear and U form types...

Страница 2: ...SIT 579 DBC type automatic burner control 9 Optional accessories 9 Electrical connection 10 Protective distances 10 Combustion air supply 12 6 exhaust system possibilities 12 Exhoust out taking combus...

Страница 3: ...ces ATTENTION Fire burning inhalation and explosion hazard Keep all flammable objects as follows building materials papers or carton unites away from heater according to the instructions Never use thi...

Страница 4: ...way the children and animals from the equipment Never service mend such devices which are hot and during operation or electrical charged Never mount such air duct unit on front or back side of device...

Страница 5: ...he closest dealer www pakole com and ask for further informations ATTENTION COMPULSORY EARTHING ATTENTION ONLY QUALIFIED PERSON CAUTION DANGER CAUTION ELECTRIC SUPPLY According to the installation pro...

Страница 6: ...he unpacking process of the appliance unload the burner the tubes and the accesories from the card board box do not remove the protection cap from the burners gas connection or from the gas joining se...

Страница 7: ...air Reflector Electrical connection Components of I form tube radiant heater assembly distances Combi hanger Burner Reflector hanger Tube connection U element Components of U form tube radiant heater...

Страница 8: ...unded power supply system If the above instructions are not followed that can lead to death heavy injuries or property demages PLEASE CHECK THE EARTHING VIGY ZAT VESZ LY VIGY ZAT RAM ELL T S FIGYELEM...

Страница 9: ...ny stage continuously to 50 of performance where the control keeps it during this time till the temperature reaches the setted temperature After these the thermostat sut off the appliance Type of ther...

Страница 10: ...EASE CHECK THE EARTHING VIGY ZAT VESZ LY VIGY ZAT RAM ELL T S FIGYELEM F LDEL S KIALAK T SA SZ KS GES Electrical connection Heat radiated area From flammable materials it is obligatory to keep SAFETY...

Страница 11: ...the number and exact position of appliances and hangers you have to provide for hanging them at a minimum of 400 mm hanging chains for example This is necessary so it does not hinder the length chang...

Страница 12: ...not exceed 15 m in lenght Maximum two 90 elbows may be used 10 picture Outside combustion air supply Inhale opening End plate Exhaust arrangements of combustion products Flue channel to the outside of...

Страница 13: ...least higher than 1 m from openings sucking hole of vent etc of force assisted ventilation systems The bottom side of exit opening must be minimum from 30 cm any kind of frontal wall protruding Exhau...

Страница 14: ...mon exit flue B33 15 picture Common flue vent set Zenit Tube Radiant Heaters Zenit Tube Radiant Heaters 16 picture Side wall flue vent set Exhoust out taking combustion air intaking A Coaxial side wal...

Страница 15: ...wall flue vent and combustion air intake element 100mm INOX combustion Air tube Vertical flue vent element 18 picture Closed burning flue vent system d common flue vent set for closed burning system C...

Страница 16: ...her the set up pressure nozz le pressure is suitable for the type of gas At Natural gas depending on output 8 6 9 5 vagy 10 mbar At S gas depending on output 8 6 10 11 11 8 vagy 12 5 mbar At Propane a...

Страница 17: ...tubes by a survey In case there is lack of sealing colouring shows it c Check the condition of reflectors if necessary clean them Clean them by a soft cloth or diluted detergent d Check the suspension...

Страница 18: ...und f Supervision of electrical connection g Supervision of combustion air fan Check wheter the wheel of fan is able to revolve free and remove the possible contaminations from revolving blades Mainte...

Страница 19: ...x x x x x x ZENIT 80 22 14 7 21 9 12 8 x x x x x x ZENIT 80 24 16 24 4 14 8 x x x x x x ZENIT 80 26 17 4 26 2 15 9 x x x x x x ZENIT 80 28 18 7 28 4 16 8 x x x x x x ZENIT 80 30 20 1 30 6 17 8 x x x...

Страница 20: ...7 1 03 ZENIT 80 24 16 24 4 14 8 2 56 1 55 2 04 1 24 1 97 1 2 ZENIT 80 26 17 4 26 2 15 9 2 75 1 67 2 19 1 33 2 12 1 29 ZENIT 80 28 18 7 28 4 16 8 2 98 1 76 2 37 1 4 2 3 1 36 ZENIT 80 30 20 1 30 6 17 8...

Страница 21: ...0 Minimum heat output as percentage of nominal heat output 60 8 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 64 1 Envelope insulation class U 0 0 W m2K Radiant factor at m...

Страница 22: ...10 Minimum heat output as percentage of nominal heat output 60 3 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 66 1 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 23: ...20 Minimum heat output as percentage of nominal heat output 60 7 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 66 9 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 24: ...90 Minimum heat output as percentage of nominal heat output 60 7 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 67 7 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 25: ...60 Minimum heat output as percentage of nominal heat output 58 4 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 66 3 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 26: ...70 Minimum heat output as percentage of nominal heat output 54 9 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 67 7 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 27: ...20 Minimum heat output as percentage of nominal heat output 57 8 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 67 6 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 28: ...10 Minimum heat output as percentage of nominal heat output 57 7 Radiant factor Envelop losses Radiant factor at nominal heat output RFnom 67 9 Envelope insulation class U 0 0 W m2K Radiant factor at...

Страница 29: ...rized retailer or service station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case of accidentally happened or directly caused mistake...

Страница 30: ...PAKOLE TRADE Ipari s Kereskedelmi Kft H 8000 Sz kesfeh rv r B rg ndi t 8 10 http www pakole com E mail mail pakole hu Tel 36 22 316 484 Fax 36 22 316 074 www pakole com...

Отзывы: