background image

GUARANTEE AND SERVICES

PRESERVE THIS WARRANTY 

Type:

Serial no.:

Date of purchasing::

LIMITED GUARANTEE *

The manufacturer guarantee the costumer that the product and its parts are free from 

material and production failures. During normal use the warranty is 2 years. This warranty 

concerns the first retail customer.

The guarantee concerns the costs of laboratory investigations and the parts, which are 

needed for proper operation. The delivery and unforeseeable costs belong also to the 

mending costs and do not contain compensation costs.

Guarantee mending can only be realized by authorized retailer or service centre.

The guarantee does not concerns the following failures, which are caused by: improper 

using,damaging,neglect,accident,lack of maintenance,normal attrition,

transformation,modification and operation influenceable factor,contaminated fuel, installa

-

tion of non-suitable part and mending which is done by not authorized retailer or service 

station.

The regular maintenance is the owner’s responsibility.

The manufacturer does not assume the responsibility in case of accidentally happened or 

directly caused mistake  respectively improper using.

*We reserve the right to change of this specification without extra notification. The 

guarantee can be applied in accordance with above defined. 

Additional guarantee is not accepted�

Guarantee servicing

If your appliance needs guarantee service in that case it can be requested at nearest au-

thorized service station giving in the appliance for repairs. 

Mending services

Take the appliance to the nearest authorized service station. If the device is not under guar-

antee the service cost will be invoiced to the costumer at defined price. The service centres 

are independent from one another and may have different owners. We reserve the right to 

change of this specification without extra notification. If you would like to contact us the type 

and serial number of device always be at hand.

Содержание ACR PRO

Страница 1: ...eration and Maintenance Documentation www pakole com ACR_Pro_008_025_011_210617_V004_EN Type ACR Pro ACR Pro 1500H ACR Pro 2000H ACR Pro 1500C ACR Pro 2000C ACR Pro 1500E ACR Pro 2000E ACR PRO AIR CUR...

Страница 2: ...SAFETY PRINCIPLES 3 2 PURPOSE OF THE DEVICE 4 3 BASIC TECHNICAL PARAMETERS 4 4 DIMENSION 5 5 HEAT OUTPUT RANGES 6 6 ASSEMBLY 7 7 CONTROLLER INSTALLATION 9 8 ELECTRICAL CONNECTION DIAGRAMS 11 9 WATER C...

Страница 3: ...tain is connected directly to the cable please make sure there is a splitter protecting against any undesired discon necting Pay special attention while transporting the device not to damage the casin...

Страница 4: ...ehouse and production halls Loading unloading sections in supermarkets and large commercial premises Car showrooms and service stations exhibition surfaces 3 BASIC TECHNICAL PARAMETERS for water param...

Страница 5: ...5 Acr Pro air curtains Operation and Maintenance Documentation 4 DIMENSIONS ACR Pro 1500H ACR Pro 1500E ACR Pro 1500C ACR Pro 2000H ACR Pro 2000E ACR Pro 2000C...

Страница 6: ...n the heaters surface as well as larger energy exchange surface ACR Pro 1500H inlet outlet water temperature 60 40 70 50 80 60 90 70 inlet air temperature 0 5 10 15 20 0 5 10 15 20 0 5 10 15 20 0 5 10...

Страница 7: ...work is possible to be conducted On both connection nozzles manual shut off valves should be installed in case of the necessity of disconnecting the unit The hot water medium supply must be connected...

Страница 8: ...utlet of the curtain is as close as possible to the doorway and air gap is at the height of the upper edge of the entry Please make sure to keep the distance of about 300 mm between the outlet casing...

Страница 9: ...UARD PRO Control room temperature by opening closing the vale or by adjusting air volume automatically Antifreeze mode protection against dropping room temperature below critical level 5 15 C Possibil...

Страница 10: ...FAN Change of the fan speed to low medium high or automatic Hold FAN for 5 seconds Manual calendar programming Monday Friday Saturday Sunday 6 settings per day BMS Functions When Panel Intelligent is...

Страница 11: ...ating Power cable and a main switch are not included in the set Also the DOORSTOP door contact switch can be installed it turns off the ACR Pro curtain when the door is being closed and the mo ment th...

Страница 12: ...curtains Operation and Maintenance Documentation 8 1 Connection scheme for 1 unit ACR Pro H or C type with Comfort controller ACR Pro E 8 2 Connection scheme for 1 unit ACR Pro E type with Comfort con...

Страница 13: ...urtains Operation and Maintenance Documentation 8 3 Connection scheme for ACR Pro H or C type with custom controller 8 4 Connection scheme for ACR Pro E type with custom controller ACR Pro ACR Pro ACR...

Страница 14: ...Acr Pro air curtains Operation and Maintenance Documentation 8 5 Connection scheme for 6 unit ACR Pro H or C type with Multi 6 and Comfort ACR Pro ACR Pro ACR Pro ACR Pro ACR Pro ACR Pro ACR Pro ACR P...

Страница 15: ...Pro air curtains Operation and Maintenance Documentation 8 6 Connection scheme for 6 unit ACR Pro E type with Multi 6 and Comfort ACR Pro E ACR Pro ACR Pro E ACR Pro E ACR Pro E ACR Pro E ACR Pro E AC...

Страница 16: ...s made of copper as well as other elements of the hy draulic system circulation The liquid must be diluted with water accordingly to the manufacturer s recommendation NOTICE Any and all repair and mai...

Страница 17: ...suitable part and mending which is done by not authorized retailer or service station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case...

Страница 18: ......

Страница 19: ......

Страница 20: ...PAKOLE TRADE Kft H 8000 Sz kesfeh rv r B rg ndi t 8 10 www pakole com mail pakole hu Tel 36 22 316 484 Fax 36 22 316 074 www pakole com...

Отзывы: