OPERA
TING
- 11 -
- MANUAL FEED : Press this button for
more than three seconds, then the
machine will run.
- TOTAL COUNTER : Press this button
to view the total count for the
machine.
- RESET : Press this button after
clearing paper jams.
Reset
Total
counter
Manual
feed
Reset
counter
Thickness
Count
BUTTONS
SETUP MODE
In order to gain access to the setup mode, please press down the reset button
while turning the power off and back on. Release the reset button once you are
in the setup mode. In order to make changes with the setting, press the reset button
to view different setup menu. Once you are in your desired menu, press the reset
counter button to change the PT-Level, DF-Level, Printer Speed, and batch counter.
1) PT-Level -
IM-4000
displays the thickness of each processed forms.
IM-4000
is set to recognize the thickness of the very
first form that was inserted into the machine. The following forms are
then scanned by the sensors and any forms that are out of the
calibrated setting are diverted into the by-pass tray. Please read the
following examples to better understand this setting.
PT-Level indicates the intensity of the sensor. It is recommended that
the PT-Level (default : 30) remains at a default setting, however,
depending on the customer needs, it can be modified to cope with
different types of forms. Please read the following examples to better
understand
this
setting.
Ex) If the first form that was inserted into the machine has the
thickness of 50 and the PT-Level is set at 30, by increasing the PT-
Level in decrease the value of the thickness. So if the PT-Level is
increased to 40, the thickness of the same form which read 50 at
PT-Level 30 will read a value below 50.
PT-Level can be set from 20 to 60 in 5’s.
2) DF-Level - DF-level (default :50) is the forgiveness percentage for the user to set
in order to avoid any unwanted forms to be processed. DF-Level of 50
means that the forgiveness level is set at 50%. Therefore the machine
is programmed to accept any forms with the thickness that fall in
between 50% from the value of the thickness of the very first form.
If you choose not to use this system, please set the DF-Level to ‘off’.
DF-Level can be adjusted from 5% to 50%. Please read the
following examples to better understand this setting.
Ex) If the first form that was inserted into the machine has the
thickness of 50 and the DF-Level is set at 50, any following forms
with the thickness of greater than 75 or less than 25 are diverted
into the by-pass tray.
DF-Level can be set up to 50 in 5’s. In order to disable this function
please set the DF-Level to “off”.
Содержание IM- 4000
Страница 6: ......