Appendix A - Specifications
150-388-151-01, Revision 01
60
September 15, 1999
HLU-388 List 5A
HLU-388 L
IST
5A C
ARD
C
ONNECTOR
shows the card-edge connector on the HLU-388 List 5A. Active pins are highlighted in black.
Figure 29.
HLU-388 List 5A Card-edge Connector
Network Management Control Bus
The HLU-388 List 5A provides a Network Management Control Bus on pin 104 of the card-edge connector. This
allows the various PairGain Management System protocols to manage the HLU through the HMU-319 HiGain
Management Unit. When the HLU-388 is under management, the
MNGD
message displays periodically on the
HLU-388 List 5A front-panel display.
Fuse Alarm
Pin 117 on the card-edge connector is a Fuse Alarm that is driven to -48 Vdc through a 1000
Ω
resistor when the
onboard fuse opens.
Some features of the HLU-388 List 5A are affected when it is under management. Consult the
management unit practice for further information.
106
105
104
103
102
101
100
DSX-1 RCV
DSX-1 XMT
HDSL 2
HDSL 1
205
204
203
202
201
200
119
118
117
116
115
114
113
112
111
110
Ground
Ground
Frame ground
Fuse Alarm*
Ring1
Ring1
Tip1
Tip1
(Mgmt.bus)
Ring
Ring
Tip
Tip
(Factory burn-in)
-48Vdc
219
218
217
216
215
214
213
212
211
210
209
208
207
206
109
108
107
* Fuse alarm is normally floating (0 to 80 Vdc max.) and
at -48 Vdc (10mA max.) when activated.