Section 363-746-100

Revision 01

Page 9

TABLE 3.  FRL-746 RT LINE UNIT TROUBLESHOOTING

Indication

Problem

Action

POWER
LED 

off

1. One or both HDSL lines

are no longer connected
between the COT and
RT. Verify the
connections at the RT
and COT.

a. Make the following measurement on the RT Enclosure backplane:

• 

130 Vdc to 250 Vdc between A_HDSL_T and B_HDSL_T

b. Make the following measurements on the COT Shelf backplane:

• 

-130 Vdc, ±10%, between A_HDSL_T1 and Chassis Ground

• 

0 Vdc to +120 Vdc, between A_HDSL_T2 and Chassis Ground

(Note: Use B_HDSL_T1 and B_HDSL_T2 for System #2)

2. The COT Line Unit fuse

F1 has blown.

Replace the fuse.

3. The RT Line Unit power

supply has failed.

Replace the RT Line Unit.

4. The COT HDSL power

supply has failed.

Replace the COT Line Unit.

Indication

Problem

Action

LOOP 1
(2) SYNC
LED
flashing or
off

1.  The HDSL line is

attempting to synchronize
with the Central Office
unit or cannot detect the
HDSL signal from the
Central Office unit. This
is usually an indication
that there is a problem
with the HDSL circuit
between the COT and RT
(assuming the FAULT
LED is 

off).

2.  COLU and RTLU

incompatible i.e. one is a
T1 version and the other
is an E1.

a) Verify the HDSL circuits are terminated properly and with the

correct orientation.

b) Measure the loop resistance of each HDSL circuit (shorting the

pair at the far end). The loop resistance must be less than that
shown in Table 1.

LOOP 1
(2)
MARGIN
LED 

on

The HDSL line margin level

is below a preset level.

See the previous discussion on the SYNC LED 

flashing or off.

FAULT
LED 

on

Faulty FRL-746 RT Line

Unit.

Replace the RT Line Unit.

Содержание PG-FLEX FRL-746 List 1

Страница 1: ...IONAL DESCRIPTION 6 OPERATIONAL CAPABILITIES 4 7 FRONT PANEL 5 8 TERMINAL MANAGEMENT 6 C INSTALLATION AND TEST 9 UNPACKING 8 10 TURN UP AND TESTING 8 11 TROUBLESHOOTING 8 CAUTION This product incorpor...

Страница 2: ...t or Pair Gain Test Controller Interface Unit in each shelf provides an interface for maintenance alarm relays and metallic access to the remote subscriber lines Remote Terminal RT The RT Enclosure pr...

Страница 3: ...ropped when 116V is applied to the subscriber s COT tip for 1 5 seconds then removing the 116 V 2 09 Test access may also be activated through the RS 232 Maintenance Port located on the front of the C...

Страница 4: ...e PairGain will repair or replace any unit without cost during this period if the unit is found to be defective for any reason other than abuse or improper use or installation 5 02 This module should...

Страница 5: ...n HDSL line 2 is attempting to synchronize with the remote unit Off HDSL line 2 does not detect an active remote unit LOOP 2 MARGIN LED Indicator Yellow HDSL line 2 margin is below a preset level Off...

Страница 6: ...ption A from the Main Menu the technician can Display System Status to show the equipment installed in the system and the current status in alarm or not of the equipment An next to the unit name indic...

Страница 7: ...terminal Login Status Main Menu Inventory Setup System Status Channel Status HDSL Status HDSL 24 Hour Perform ance History HDSL 7 Day Performance History System Setup System Date System ID System Tim...

Страница 8: ...rve normal electrostatic discharge precautions when handling electronic equipment Do not hold electronic plug ins by their edges Take care not to touch components or circuitry Step Operation Action Ob...

Страница 9: ...COT HDSL power supply has failed Replace the COT Line Unit Indication Problem Action LOOP 1 2 SYNC LED flashing or off 1 The HDSL line is attempting to synchronize with the Central Office unit or cann...

Страница 10: ...loop attenuation to the 2B1Q signal than the 278 kHz loss The normal range of pulse attenuation is from 1 to 32 dB PPM Indicates the relative offset of the crystal oscillator in the RT Line Unit from...

Отзывы: