System Configuration
700-814-112-01, Revision 01
14
November 24, 1999
UTU-814 List 1B
System Setting
Description (
settings in boldface type are default settings)
Remote Power
Feed Loop
No selection available.
BOTH
BOTH is displayed in UNSTRUCT, STRUCT, and TSP application
modes. The LTU uses Loop 1 and Loop 2 to supply power to the NTU.
LOOP1
LOOP1 displays in SINGLE application mode when POWER is selected
for Remote Power Feed mode. This is followed by the warning
NTU
LOCAL
POWER
REQUIRED,
PROCEED ANYWAY
(Y/N)
.
Remote Console
Access
Select whether system settings can be made from the NTU console
screen or the settings are read-only. This option is set only at the LTU.
ALLOWED
NTU console screens can be used to make system settings.
BLOCKED
NTU console screens are read-only. The LOC and REM pushbuttons
on the NTU are also disabled. System settings can be made only from
the LTU console screen.
Protection Switch
Command
Not supported.
Local Unit Role
(LTU or NTU)
Configures the UTU-814 as LTU (master) or NTU (slave). The default
configuration is NTU (slave). Note that changing the Local Unit Role
of the UTU-814 causes the unit to reset and the LEDs to cycle.
LTU
Configures the UTU-814 as LTU (master). The LTU-configured
UTU-814 does not provide line power to other HDSL units.
NTU
Configures the UTU-814 as NTU (slave). The NTU-configured
UTU-814 cannot receive power from another UTU; it can, however,
receive power from a conventional LTU.
Table 4.
Settings in Config System Settings Menu (Cont.)