PairGain HiGain-2 HRU-612 Скачать руководство пользователя страница 4

Section 150-612-102
Revision 03

Page 4

4.04

Refer to the installation section of the 
appropriate instruction manual for the unit

you are installing for:

• 

Cabling information

• 

Proper connections

• 

Grounding information

• 

Line vs local power

All wiring external to the product(s) should follow the
provisions of the current edition of the National
Electrical Code.

5.  WARRANTY

5.01

PairGain Technologies warrants this product
to be free of defects and to be fully

functional for a period of 36 months from the date of
original shipment, given proper installation and
regular maintenance.  PairGain will repair or replace
any unit without cost during this period if the unit is
found to be defective for any reason other abuse or
improper use or installation.

5.02

This module should not be field repaired.  If 
it fails, replace it with another unit and return

the faulty unit to PairGain for repair.  Any
modifications of the unit by anyone other than an
authorized PairGain representative will void the
warranty.

5.03

If a unit needs repair, call PairGain for a 
Return Material Authorization (RMA)

number and return the defective unit, freight prepaid,
along with a brief description of the problem, to:

PairGain Technologies, Inc.
14402 Franklin Avenue
Tustin, CA 92680
ATTN: Repair and Return Dept.
(714) 832-9922
(800) 638-0031

5.04

PairGain will continue to repair or replace 
faulty modules beyond the warranty

program at a nominal charge.  Contact your
PairGain sales representative for details and pricing.

6.  TECHNICAL ASSISTANCE

6.01

PairGain Technical Assistance is available 
24-hours-a-day, 7-days-a-week by

contacting PairGain’s Customer Service Engineering
group at one of the following numbers:

Telephone:

(800) 638-0031

(714) 832-9922

Fax:

(714) 832-9924

During normal business hours (8:00 AM to 5:00 PM,
Pacific Time, Monday - Friday, excluding holidays),
technical assistance calls are answered directly by a
Customer Service Engineer.  At other times, a
request for technical assistance is handled by an on-
duty Customer Service Engineer through a callback
process.  This process results in a callback within 30
minutes of initiating the request.

In addition, PairGain maintains a computer bulletin
board system for obtaining current information on
PairGain products, product troubleshooting tips and
aids, accessing helpful utilities, and for posting
requests or questions.  This system is available 24-
hours-a-day by calling (714) 730-3299.
Transmission speeds up to 28.8 kbps are supported
with a character format of 8-N-1.

B. FUNCTIONAL DESCRIPTION

7.  FUNCTIONAL OPERATION

7.01

HiGain-2 utilizes PairGain’s 2B1Q VHDSL 
transceiver technology to establish a full-

duplex 1568 Kbps data channels between the HLU
and a remotely mounted HRU-612 HiGain-2 Remote
Unit.

7.02

The HRU-612 power supply converts the 
metallic 170 Vdc power feed that is received

on the VHDSL pair to voltages and currents required
by the HRU-612 circuitry.  The power supply
gen5, -5 and 30 Vdc outputs.  The 30V
output is converted to a 60 mA current feed used to
simplex power the NID (Network Interface Device).
Caution should be used when the HRU is used to
power CSUs.  Some CSUs require more output
voltage than the 30 volts provided by the HRU.  The
HRU can not power both an NID and a CSU at the
same time.

Содержание HiGain-2 HRU-612

Страница 1: ...IONS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 3 5 WARRANTY 4 6 TECHNICAL ASSISTANCE 4 B FUNCTIONAL DESCRIPTION 7 FUNCTIONAL OPERATION 4 8 FRONT PANEL 6 9 OPTIONS 7 10 LOOPBACKS 9 C INSTALLATION AND TEST 1...

Страница 2: ...smart jack loopback Conforms to TR TSY 000312 Provisioning switches for CPE current RCV LBO and XMT LOS initiated loopback or AIS Front panel jacks for test access RS 232 front panel terminal access f...

Страница 3: ...50 Celsius 5 to 95 non condensing Mounting Single width 400 type mechanics slot Dimensions 5 6 H x 1 4 W x 5 6 D 4 CERTIFICATION 4 01 FCC Compliance The HRU 612 List 2 has been tested and found to co...

Страница 4: ...Technical Assistance is available 24 hours a day 7 days a week by contacting PairGain s Customer Service Engineering group at one of the following numbers Telephone 800 638 0031 714 832 9922 Fax 714 8...

Страница 5: ...the screen displays The port is configured as DCE with 8 data bits 1 stop bit and no parity Striking the SPACE bar several times invokes autobaud from 1200 to 9600 baud Note that if the RS 232 port in...

Страница 6: ...B NET GREEN LED indicating the HRU is in a loopback state in which the signal from the NETwork is being looped back to the NETwork CI YELLOW LED indicating the HRU is in a loopback state in which the...

Страница 7: ...611 100 for more details The HRU also has three user options set by switches located at the back of the unit as shown in Figure 4 Each switch has two settings as follows refer to the block diagram in...

Страница 8: ...en the HRU does not function as the NID but is connected to an external NID It allows the external NID to set the appropriate NI level 15 Configures the T1 RCV LEVEL to 15 dB This sets the T1 output s...

Страница 9: ...t jack loopback state It remains in this state until a loopdown command is detected or the default time out period if enabled expires 10 04 When the HRU is in its AIS ENA smart jack metallic loop back...

Страница 10: ...ed or unframed The loop down command for both is the standard 3 in 5 five second pattern C INSTALLATION AND TEST 11 INSTALLATION 11 01 Upon receipt of the equipment visually inspect it for signs of da...

Страница 11: ...e C O 7 To verify that the proper ports are use for the VHDSL DS1 pairs use an ohm meter to verify that the VHDSL HRU 612 port has a 180 k T to R resistive signature in contrast to the DS1 ports which...

Страница 12: ...ustomer at HRU 612 NREM Network Remote Loopback DSX signal is looped back to DSX at HRU SMJK Remote Smartjack Loopback Signal from DSX is looped back at HRU by the HRU smartjack module TLOS Transmit L...

Страница 13: ...ng System Settings review mode defined above FRM Frame SF ESF UNFR NONE Defines the type of frame pattern being received from the DSX 1 Displayed during System Settings mode defined above CODE Line Co...

Страница 14: ...tiated by 2 in 5 in band loopback code or out of band ESF data link code See Figure 5 NREM Network Remote Loopback Loopback at HRU remote towards network initiated from C O network by intelligent line...

Страница 15: ...Hour ES Errored Seconds The number of 1 second intervals that contained at least 1 CRC error This value is a running total of the last 24 Hours VHDSL 24 Hour UAS Unavailable Seconds The number of sec...

Страница 16: ...Section 150 612 102 Revision 03 Page 16 Figure 7 HRU 612 Maintenance Terminal Main Menu Figure 8 HRU 612 View Span Status Display...

Страница 17: ...Section 150 612 102 Revision 03 Page 17 Figure 9 HRU 612 System Settings Menu Figure 10 HRU 612 Set Clock Menu...

Страница 18: ...Section 150 612 102 Revision 03 Page 18 Figure 11 HRU 612 View Performance Data Display Figure 12 HRU 612 View Performance History Display...

Страница 19: ...2 102 Revision 03 Page 19 Figure 13 HRU 612 View Alarm History Display Copyright 1996 PairGain Technologies Inc PairGain is a registered trademark CopperOptics and HiGain are trademarks of PairGain Te...

Отзывы: