150-431-115-01, Revision 01
System Alarms
HLU-431 List 1E
September 22, 1998
35
S
YSTEM
A
LARMS
lists possible HLU-431 alarm states. The accompanying front panel message is listed in the Alarm
column. More than one alarm condition can exist at any given time, but only one message can be displayed. For
multiple alarms, only the highest priority alarm displays.
R
ETIRING
S
YSTEM
A
LARMS
To retire a system alarm, press the SEL button and execute an Alarm Cut Off (ACO). An ACO turns the alarm off
and replaces the
ALRM
message with an
ACO
message. The second part of the
ALRM
message, which defines the
cause of the alarm, remains. Both parts of the message remain until the alarm condition clears or another higher
priority alarm occurs.
Table 12.
HDSL System Alarms
Front Panel
Message
Alarm
Description
To Inhibit:
ALRM LOSW
Loss of Sync Word
a
a When both HDSL loops lose sync word (LOSW), a system alarm condition exists. However, since the HLU-431 enters a self
test cycling mode, the front panel LED lights yellow instead of red and the
SELF TEST
message displays instead of the
ALRM
message.
One of the HDSL loops has lost
synchronization.
Cannot be inhibited.
ALRM LLOS
Local Loss of Signal Loss of the DSX-1 input signal.
Cannot be inhibited.
ALRM RLOS
Remote Loss of
Signal
Loss of the HRU DS1 input signal.
Disable the RDA (Remote DS1 Alarm)
option. This prevents an LOS condition at
the DS1 input to a HRU from activating Pin
H. The front panel Status LED still flashes
red and the ALRM RLOS message displays
to alert you of the LOS state. LOS is sent
towards the network from the HLU. This
option prevents the common occurrences
of a CPE LOS condition from generating
recurring alarms and AIS payloads.
ALRM TLOS
Transmit Loss of
Signal
The DS1 input is not present at the HRU.
Places the HRU in loopback towards the
network.
Set the TLOS switch at the HRU to disable.
ALRM H1ES
or
ALRM H2ES
Errored Second
Rate exceeded
The number of errored seconds on HDSL
Loop 1 or Loop 2 has exceeded the
threshold value set by the terminal ES
ALARM THRES option.
Set the Errored Second Threshold option to
0 (zero).
ALRM DS1
Bit Error Rate
exceeded
The combined T1 and HDSL BER has
exceeded you set threshold limits of 10
-6
or 10
- 7
.
Select NONE for the BER system option.
ALRM MAL1
or
ALRM MAL2
Margin Alarm
Loop1
or
Margin Alarm
Loop2
The margin on HDSL Loop 1 or Loop 2 has
dropped below the minimum threshold
value set by the terminal MARGIN ALARM
THRES option.
Set the Margin Alarm Threshold option to 0
(zero).