![PairGain 150-1504-15 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/pairgain/150-1504-15/150-1504-15_manual_747285039.webp)
150-431-115-01, Revision 01
Maintenance
HLU-431 List 1E
September 22, 1998
29
Errored and Unavailable seconds are defined in
.
From each Performance Data screen you can do the following:
•
Press
to view the previous 4-hour data screen.
•
Press
to view the next 4-hour data screen.
•
Press to exit.
•
Press
to view the next available span.
Performance Data Screen: No Doubler
Press
from the Maintenance Terminal Main Menu to view the Performance Data screen for applications (
) without a doubler. This screen shows the Errored and Unavailable Seconds for the HDSL span between the
HLU-431 and the HRU.
Figure 15.
Performance Data Screen: No Doublers
Table 10.
Errored and Unavailable Seconds Definitions
ES and UAS
Definition
HDSL Errored Second
A second in which at least one HDSL CRC has occurred.
HDSL Unavailable Second
A second in which an HDSL loop has sync loss at least once.
DS1 Errored Second
A second in which at least one BPV has occurred.
DS1 Unavailable Second
A second in which at least one T1 LOS condition (175 ± 75) zeros has occurred.
Date: 02/02/98 PERFORMANCE DATA
CIRCUIT ID#:
ERRORED SECONDS/UNAVAILABLE SECONDS
DS1 HDSL-1 HDSL-2
HLU HRU HLU HRU HLU HRU
20:30 000/000 000/000 000/000 000/000 000/000 000/000
20:45 000/000 000/000 000/000 000/000 000/000 000/000
21:00 000/000 000/000 000/000 000/000 000/000 000/000
21:15 000/000 000/000 000/000 000/000 000/000 000/000
21:30 000/000 000/000 000/000 000/000 000/000 000/000
21:45 000/000 000/000 000/000 000/000 000/000 000/000
22:00 000/000 000/000 000/000 000/000 000/000 000/000
22:15 000/000 000/000 000/000 000/000 000/000 000/000
22:30 000/000 000/000 000/000 000/000 000/000 000/000
22:45 000/000 000/000 000/000 000/000 000/000 000/000
23:00 000/000 000/000 000/000 000/000 000/000 000/000