background image

Revision 01

July 30, 1999

Section 363-703-142

FLC-703, List 4B

PairGain Engineering - Plant Series

Page 9

Indication

Problem

Action

Can’t Hear,
Can’t Be
Heard

subscriber problem

faulty RT or COT
Channel Unit

1

Lift the subscriber line at the network interface and check the signal
level.  If correct, refer trouble to the customer per local practice.

2

If the level is too low, check the level at the RT.  If the level is correct
at the RT, check the pair between the RT and the network interface.  If
the level is too low at the RT, replace the RT Channel Unit.

3

If the level is still too low, re-insert the original RT Channel Unit.

4

Check the level at the COT coming from the CO switch.  If it is correct,
replace the COT Channel Unit.  If it is not correct, refer the problem to
the CO regarding the switch.

5

If the level is still not correct, re-insert the original COT Channel Unit.
Contact PairGain technical assistance per section 9.

D. TECHNICAL SUPPORT

9.  Technical Support

9.1

PairGain Technical Assistance is available 24-hours-a-day, 7-days-a-week by contacting PairGain
Customer Service Engineering group at:

Telephone:

(800) 638-0031 or (714) 832-9922

Fax:

(714) 832-9924

9.2

During normal business hours (8:00 AM to 5:00 PM, Pacific Time, Monday - Friday, excluding
holidays), technical assistance calls are normally answered directly by a Customer Service Engineer.
At other times, a request for technical assistance is handled by an on-duty Customer Service
Engineer through a callback process.  This process normally results in a callback within 30 minutes
of initiating the request.

9.3

In addition, PairGain maintains a computer bulletin board system for obtaining current information
on PairGain products, product troubleshooting tips and aids, accessing helpful utilities, and for
posting requests or questions.  This system is available 24-hours-a-day by calling (714) 730-3299.
Transmission speeds up to 28.8 kbps are supported with a character format of 8-N-1.

E.  CERTIFICATION AND WARRANTY

10.  Certification

10.1

FCC Compliance. This product complies with the limits for Class A digital devices pursuant to Part
15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.

Содержание 150-1303-42

Страница 1: ...L CENTRAL OFFICE TERMINAL LOOP START GROUND START UNIT Model List Number Part Number CLEI Code FLC 703 4B 150 1303 42 VACHLHGC PAIRGAIN TECHNOLOGIES INC ENGINEERING PLANT SERIES TECHNICAL PRACTICE SEC...

Страница 2: ...amage A warning indicates the possibility of personal injury A PRODUCT OVERVIEW 1 1 Description and Features 1 2 Front Panel 2 3 Specifications 3 B Functional Description 4 4 Applications 4 5 Operatio...

Страница 3: ...unit provides metallic test access to the subscriber line connection through an optional metallic bypass pair Perform metallic bypass testing either manually or through the Pair Gain Test Controller...

Страница 4: ...different states and indications for the FLC 703 Channel Unit front panel LEDs Figure 1 FLC 703 Front Panel Table 1 FLC 703 Front Panel LEDs LED LED State Indicates Solid green Channel is off hook ACT...

Страница 5: ...5 dB 1 0 Ring Ground Resistance 500 Channel Signature Loop Start Lines Ground Start Lines Tip Ring open 23 75 k 1 Tip Ground 162 k 1 162 k 1 Ring Ground 226 k 1 226 k 1 Environmental Operating Elevati...

Страница 6: ...cal system with loop start and ground start services Figure 2 Typical System with Loop Start and Ground Start Capabilities 5 Operational Capabilities 5 1 FLC 703 Functions The FLC 703 Channel Unit pro...

Страница 7: ...egative at the RT The following occurs when a PBX requests service for an outgoing call by grounding the Ring lead at the RT FRC 753 signals the FLC 703 FLC 703 operates a Ring ground relay that reque...

Страница 8: ...ed period store the equipment in its original container 7 Installation Observe normal electrostatic discharge precautions when handling electronic equipment Do not hold electronic plug ins by their ed...

Страница 9: ...t per section 7 2 a Place an outgoing call for each subscriber circuit provisioned and observe that the appropriate ACTIVE LED tracks the progress of the call Table 1 b Place an incoming call for each...

Страница 10: ...r the problem to the customer per local practice 2 If ringing is not present check for ringing at the RT If ringing is present check the pair between the RT and the network interface If no ringing is...

Страница 11: ...c Time Monday Friday excluding holidays technical assistance calls are normally answered directly by a Customer Service Engineer At other times a request for technical assistance is handled by an on d...

Страница 12: ...replace any unit without cost during this period if the unit is found to be defective for any reason other than abuse or improper use or installation 11 2 This module should not be field repaired If...

Страница 13: ...viations CLASS Custom Local Area Signaling Services CO Central Office COT Central Office Terminal DTMF Dual Tone Multi Frequency MLT Mechanized Loop Testing PBX Private Branch Exchange PCM Pulse Code...

Страница 14: ......