4. TESTING PROCEDURES
4.01
Table 8 lists the four-character front panel
message displays of the ELU-319. This
display energizes when power is initially applied to
the ELU-319; it indicates system status and error
conditions. In order to conserve power, the display
de-energizes after five minutes if neither MODE or
SEL are pressed. The use of either button restarts
the 5-minute power-control timer.
4.02
If you encounter trouble with the G.703
interface, verify that the unit is making a
positive connection with the mounting assembly's
connector.
4.03
The transmit and receive G.703 ports have
splitting access and bridging miniature 210-
type jacks as shown in Figure 2. Connecting one
cable between the two BRG jacks and another cable
between the two SPAN jacks splits the XMT and
RCV jacks and creates metallic loopbacks towards
both the G.703 and the ELU-319.
TABLE 8. ELU-319 FOUR-CHARACTER FRONT PANEL MESSAGES
Message
Full Name
Description
CREM
Customer Remote Loopback
Signal from customer is looped back to customer at ELU-319.
NLOC
Network Local Loopback
G.703 signal is looped back to G.703 at ELU-319.
HDU1
Network Doubler 1 Loopback
Loopback at Doubler #1 towards network initiated by ELU-319
front panel MANUAL LOOPBACK push-buttons or maintenance
terminal (Figure 14).
HDU2
Network Doubler 2 Loopback
Loopback at Doubler #2 towards network initiated by ELU-319
front panel MANUAL LOOPBACK push-buttons or maintenance
terminal (Figure 14).
CDU 1
Customer Doubler 1 Loopback
Loopback at Doubler 1 towards CI initiated by ELU-319 front
panel MANUAL LOOPBACK push-buttons or maintenance
terminal (Figure 14).
CDU 2
Customer Doubler 2 Loopback
Loopback at Doubler 2 towards CI initiated by ILR code, ELU-
319 front panel MANUAL LOOPBACK push-buttons or
maintenance terminal (Figure 14).
CLOC
Customer Local Loopback
Signal from Customer is looped back to customer at ERU-412.
NREM
Network Remote Loopback
G.703 signal is looped back to G.703 at the ERU-412.
TLOS
Transmit Loss Of Signal
ERU-412 is in a logic loopback state caused by a loss of its
G.703 input from the NI, if enabled via the ERU-412 TLOS
switch option set to ON.
LBPV
Local Bipolar Violation
A bipolar violation has been received at the G.703 input to the
ELU-319.
SIG 1 or 2
Signal 1 or Signal 2
The ELU and first doubler transceivers are trying to establish
contact with each other on Loops 1 or 2 of Span 1.
S2L1 or 2
Signal 2 Loop 1 or Loop 2
The 1st doubler and ERU or 2nd Doubler transceivers are trying
to establish contact with each other on Loops 1 or 2 of Span 2.
S3L1 or 2
Signal 3 Loop 1 or Loop 2
The 2nd doubler and ERU transceivers are trying to establish
contact with each other on Loops 1 or 2 of Span 3.
Table continued on next page
Содержание 150-1236-54
Страница 19: ...Section 150 319 254 Revision 02 Page 19 Figure 6 Main Menu Figure 7 Span Status Display no Doubler...
Страница 20: ...Section 150 319 254 Revision 02 Page 20 Figure 8 Set Clock Menu Figure 9 System Settings Menu...
Страница 32: ...Section 150 319 254 Revision 02 Page 32 Figure 15 Main Menu Figure 16 Span Status Display no Doublers...
Страница 34: ...Section 150 319 254 Revision 02 Page 34 Figure 19 Span 3 Status Display two Doublers Figure 20 Set Clock Menu...
Страница 35: ...Section 150 319 254 Revision 02 Page 35 Figure 21 System Settings Menu Figure 22 Loopback Menu one Doubler...
Страница 36: ...Section 150 319 254 Revision 02 Page 36 Figure 23 Performance Data Span 1 Figure 24 Performance Data Span 2...
Страница 37: ...Section 150 319 254 Revision 02 Page 37 Figure 25 Performance Data Span 3 Figure 26 Performance History Span 1...
Страница 39: ...Section 150 319 254 Revision 02 Page 39 Figure 29 Alarm History Span 1 Figure 30 Alarm History Span 2...