150-231-175-01, Revision 01
Loopback Operation
HLU-231 List 7E
September 23, 1998
43
5
Once the test is complete, do one of the following:
•
If the system is to loopdown but remain ARMED, send the IR (Intelligent Repeater) LPDN code
(universal loopdown).
•
If all the equipment is to be looped down, disarmed and returned to normal operation, send the disarm
code 11100.
Using the codes listed in
, a network tester can activate loopbacks NLOC or NREM or SMJK
(if enabled). A customer tester can activate loopbacks CLOC or CREM. All loopbacks shown in
can also
be initiated from the HLU-231 front panel MODE and SEL buttons (see
“Setting Options through SEL and
).
The ARMED mode has an automatic time-out of 120 minutes but this timer is reset to 120 for any
of the following events:
•
Loopback terminates (manually or time-out),
•
Query
•
Alternate query
•
Far end activate
•
Another ARM command.
Information specific to HiGain doublers is shown in bold in
.