14
Jet Swim Motion
MA30-09 GB
ENGLISH
Th
is
d
oc
um
en
t a
nd
it
s
co
nt
en
ts
a
re
th
e
ex
cl
us
iv
e
pr
op
er
ty
o
f P
ah
lé
ns
a
nd
m
ay
n
ot
b
e
co
pi
ed
,
re
pr
od
uc
ed
, t
ra
ns
m
itt
ed
o
r c
om
m
un
ic
at
ed
to
a
th
ird
pa
rty
, o
r u
se
d
fo
r a
ny
p
ur
po
se
w
ith
ou
t w
rit
te
n
pe
rm
is
si
on
.
Art.no.
Rev.no.
Scale
Designed by:
Approved by:
Revised by: Date
Drawn by: Date
Drawing number
Assembly drawing no.
Surface treatment
part of ISO 2768-1
The tolerance class in accordance with this
E
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
RJ
2017-06-07
Classic
Grundsats Jet Swim Motion
M12782 0
A
Av/På
B
Luftjustering
U1
V1
W1
2
4
6
2
4
6
14
13
1
3
5
1
K1
2,5~D
B1
M1
P
NO
COM
F1
3
5
1
3
5
A1
A1
A2
96
95
L1
L2
L3
N
M
W2 U2 V2
U1 V1 W1
U1
V1
W1
2
4
6
2
4
6
14
13
1
3
5
1
K1
1,5~D
2,5~D
B1
F2
M1
P
NO
COM
F1
3
5
1
3
5
A1
A2
2
4
1
3
96
95
L1
L2
L3
M
W2 U2 V2
U1 V1 W1
Figure 1. Front (Classic)
A
On/Off
B
Air adjustment
Start
The pump must be filled with water prior to starting.
Never run the pump dry
, as that can damage the parts inside.
1. Make sure that the pump’s direction of rotations is consistent with the arrow
on the motor’s fan cover.
2.
Open the valves.
3. Make sure that all the valves to and from the pump are open.
Make sure that the pump is completely filled with water before it is started.
4. Start the pump.
Electrical Installation
All electrical connections shall be made by an authorised electrician.
The device shall be preceded by a residual current device with a maximum breaking current of 30 mA. The pump motor is
connected via the control panel for Jet Swim Motion, see the circuit diagram. Check the rating plate on the pump motor for the
correct connection on the closing link.
Make sure that the pump motor has been connected in the correct direction of rotation (see the rotation direction arrows on the
pump motor’s fan casing). The wrong direction
can damage the pump.
N.B.! The pump must never be started without being filled with water.
Make sure that the motor guard in the control panel is set according to the rated current; see pump’s the rating plate.
Electrical Connection Diagram
3~400V
3~230V
Operation
1.
Start the jet streams with the push button (A figure 2).
2. The air mixture can be adjusted with the dial (B)
3.
Turn off the jet streams with the push button (A figure 2).
N.B!
When there is a risk of freezing, close the valves, remove and drain the pump of all water. The pump should be stored indoors.
Lower the water level to approximately 10 cm under the Jet Swim housing in order to avoid freezing damage.
Pressure
switch
Connector
Engine
circuit relay
PE
Circuit
breaker
Connector
Engine
circuit relay
PE
Pressure
switch