Heat pump Calidi XP
M
A
20-23 GB
T
ranslation of the original instructions (Swedish)
Technical
parameters
XP10
Item no. 14983340
XP15
Item no. 14983341
XP17
Item no. 14983342
XP28
Item no. 14983343
XP35
Item no. 14983344
Heating capacity
A
2.0–10.3kW*
3.0–15.0kW*
3.5–17.3kW*
5.4–27.0kW*
7.1–35.6kW*
B
1.4–7.1kW*
2.1–10.5kW*
2.3–11.4kW*
3.6–18.0kW*
4.8–24.0kW*
COP
A
6.9–14.5*
6.7–15.5*
5.9–14.8*
6.2–14.5*
5.5–14.6*
B
4.6–7.3*
4.6–7.8*
4.3–7.5*
4.5–7.6*
4.5–7.7*
COP
at 50% capacity
A
10.4*
10.9*
10.5*
10.8*
10.3*
В
6.4*
6.6*
6.1*
6.5*
6.8*
Sound pressure
at distance 1 meter
38.6–49.9 dB(A) 41.3–54.0 dB(A) 43.1–53.8 dB(A) 43.5–54.9 dB(A) 42.6–54.7 dB(A)
Sound pressure at 50% capacity
and distance 1 meter
43.3 dB(A)
46.0 dB(A)
46.5 dB(A)
48.4 dB(A)
45.8 dB(A)
Sound pressure
at distance 10 meter
18.6–29.9 dB(A) 21.3–34.0 dB(A) 23.1–33.8 dB(A) 23.5–34.9 dB(A) 22.6–34.7 dB(A)
Rated power
at air +15°С
0.19–1.5kW
0.27–2.2kW
0.3–2.6kW
0.53–3.9kW
0.62–5.2kW
Rated operation current
at air +15°С
0.83–6.5A
1.17–9.6A
1.3–11.3A
0.76–5.6A
0.89–7.4A
Electric connections
230V/1-phase/50Hz
400V/3-phase 50Hz
Max. input current
10.0A
13.5A
15.0A
7.0A
9.5A
Recommended water 昀氀ow
3–4m³/h
5–7m³/h
6.5–8.5m³/h
10–12m³/h
12–18m³/h
Pipeline water
in and out
Ø50mm
Weight
49 kg
52 kg
63 kg
93 kg
120 kg
Refrigerant
R32
Refrigerant quantity
0.75 kg
0.9 kg
1.0 kg
2.0 kg
2.7 kg
A (Ambient conditions А) = Air +26°С, Water +26°С, Humidity 80%.
B (Ambient conditions В) = Air +15°С, Water +26°С, Humidity 70%.
* Data is provided for optimal conditions.
Note!
We reserve the right to change the speci昀椀cations without prior notice.
Please note that the heat pump funkctions and parameters vary depending on the circumstances. See the rating plate on the
pump for details.
Safety
• Make sure that the main power switch is located out of reach of children.
• Never remove the protection in front of the fan.
• Never put your hands in the air outlet.
•
Turn o昀昀 the heat pump during lightning storms in order to prevent damage.
•
Do not place near the heat pump any objects that can block air昀氀ow.
•
Never use/store 昀氀ammable gaseous or liquid substances (e.g. paint thinner, paint, fuel ) near the heat pump.
•
Never attempt to repair the heat pump. In case of an unusual noise, smell, smoke or electric faults - immediately switch o昀昀 the
machine power and contact your installer.
•
If the pump has not been used for a long time: switch the power o昀昀 and drain the heat pump from water. Cover it.
Transporting
Transport the heat pump standing safely in its original packaging.
The heat pump should NOT be lifted with pipe connections since the titanium heat exchanger inside the heat pump can be damaged.
Pahlén is not responsible for any damage caused by improper handling.