Aqua-Mex heat exchanger
ENGLISH
6
Installation instruction
MA40-12E
2011
Troubleshooting
Fault
Cause - action
Heat exchanger pump
does not start
(only for Aqua-Mex FE
)
Check the fuses in the electrical control box.
Check the voltage (see data on the rating plate).
Check that the Aqua-Mex FE is being supplied with current (a dot is showing in the display).
Check that the Aqua-Mex FE is switched on (on/off button).
M+&-U(,+&(*&-5.8#0B(-)0-"),T*(?54C(=+&(?54(*4),-+(-",*(5",(4+&.(*&-5.8#0B(-)0-"),(?54()*(2&**(
than 90 litres/min.
Set a higher temperature.
Check that the motor is not blocked by built-up deposits. Undo the air screw entirely and check the
rotor’s free movement with a screwdriver.
Noise in the pump
M#1),#,)5.(.5)*&(54)./(,5(254(*,#,)-().?54(E0&**"0&C(D.-0&#*&(,+&(E0&**"0&()>(E5**)32&:(5,+&04)*&(
select a higher power output setting on the circulation pump
(only for Aqua-Mex FE).
D.*">9-)&.,(+&#,)./(
Air in the system – the system/circulation pump needs to be bled.
Select a higher power output setting on the circulation pump
(only for Aqua-Mex FE)
.
D.*">9-)&.,(*&-5.8#0B(-)0-"),(?54:(*&&(,+&(,#32&(&.,),2&8(S^&0>50F#.-&AC(
Temperature of the primary circuit’s water not high enough – check the heating source, insulate
the primary piping more effectively.
Check that the heat exchanger is installed such that the primary and secondary circuits operate in
opposite directions.
Flow noise
Lower the speed by turning down the circulation pump to a lower gear
(only for Aqua-Mex FE)
.
Error codes
<H(a(?54(*4),-+:(-)0-"2#,)5.(E"FE(
E2 = pool temperature sensor
HI = pool temperature above +45ºC