PAGlok 9661 Скачать руководство пользователя страница 2

U5007A PAGLOK POWER MODULE INSTRUCTION MANUAL

U5007A PAGLOK POWER MODULE INSTRUCTION MANUAL

7.2V Output (Model 9663):

 Maximum continuous current 1.5A.

The output is protected against short circuit and over-current.

2.6

Connections:

PAGlok: Patented professional locking connector compatible with
all PAGlok batteries. Incorporates self-cleaning military-type
beryllium-copper leaf contacts.

Remote Input:
XLR-4 male: Pin 1 negative, Pin 4 positive, Pins 2 & 3 sense.

XLR-4 Output:
XLR-4 female: Pin 1 negative, Pin 4 positive, Pins 2 & 3 sense.

NOTE: The PAGlok Power Module Interconnecting Lead (Model No.
9664) has a special wiring configuration to deliniate master/slave
Module configuration.

7.2V Output (Model No. 9663):
Pin 1: positive, Pin 2: no connection, Pin 3: negative.

2.7

User Interface:

The unit is provided with a Power switch which enables the output
power to be turned on or off. Battery status is shown by LED
indicators.

2.8

Changeover Voltage:

The unit will switch the output instantaneously from a nominally
discharged battery to a nominally charged battery when the voltage
on the discharged battery reaches 11.71V (2%). At no time are any
two batteries connected together.

2.9

Safety:

The Power Module is designed to be operated at Safety Extra Low
voltage.

2.10 European Union Directives:

Complies with EMC Directive 89/336/EU. The Power Module is
designed to be operated at Safety Extra Low voltage and therefore
falls outside the scope of the EU Low Voltage Directive.

2.11 Operating Temperature Range:

0ºC to 40ºC (+32ºF to +104ºF).

2.12 Overall Dimensions (H x W x D):

135 x 115 x 55mm (5.3" x 4.5" x 2.1" approx.).

2.13 Weight:

410gm (0.9lbs approx.).

OPERATING INSTRUCTIONS

SECT ION 3

3.1

Ensure that the Power switch is set to OFF (0).

3.2

Battery Connection - Single Power Module:

IMPORTANT: Use 12V to 14.4V batteries ONLY.

Connect charged batteries to the Power Module. Up to three
batteries may be connected to the Module, using the two PAGlok
connectors and the XLR-4 male connector labelled ‘REMOTE INPUT’.

3.3

Battery Connection - Two Power Modules:

IMPORTANT: Use 12V to 14.4V batteries ONLY.

Connect the ‘OUTPUT’ of one Power Module (which now becomes the
‘slave’ unit) to the ‘REMOTE INPUT’ of the other unit (which now
becomes the ‘master’ unit) using Power Module Interconnecting
Lead Model No. 9664. This lead incorporates a special wiring
configuration which identifies the ‘master/slave’ relationship of the
two units. Connect charged batteries to the Power Modules. Up to
five batteries may be connected, using the four Paglok connectors
and the connector labelled ‘REMOTE INPUT’ which is available on the
slave unit.

3.4

Connect the equipment to be powered to the connector labelled
‘OUTPUT’.

NOTE: Model 9663 incorporates a 7.2V output facility, which may be
used concurrently with the standard XLR-4 output. When using two
Power Modules, do not use the 7.2V output on the slave unit.

3.5

Turn the Power switch to ON (-). One of the batteries will be
connected to the output, and the LED for that channel will flash.

3.6

The LED for any other channel that has a battery connected will be
lit continuously (non-flashing).

3.7

The LED for any channel that does not have a battery connected will
not be lit.

3.8

When a battery becomes discharged down to the changeover
voltage, the LED indicator for that channel will be extinguished,
and the next battery will be instantaneously connected to the
output. The LED indicator for that channel will then commence to
flash.

3

4

Отзывы: