3.1

OPERATION OF THE ODP CIRCUIT.

Nickel-Cadmium batteries should not be discharged too deeply. If the voltage
of a battery pack falls below 75% of its nominal voltage (e.g. 9V for a 12V
battery) cells may be damaged by voltage reversal, thus shortening the life
of the battery.

To guard against this, all Pagbelts are provided with an Over-Discharge
Protection circuit which will cut power to the output connectors when the

2.4

Do not immerse the battery belt in water. Should this happen drain all excess
water and allow it to dry naturally in a warm place. Do not attempt to use or
charge the battery belt until it has fully dried.

2.5

Do not connect to mains supply while disassembled. Qualified electronics
engineers who wish to gain access to internal assemblies should note that
parts of the power circuit retain high voltage even after the mains supply has
been disconnected. Wait for a period of five minutes following disconnection
before disassembly.

2.6

The battery output is protected by means of a self-resetting over-current
device. If the output is overloaded, the device will trip, causing the output
to become open circuit. In this event, disconnect any equipment from the
output, and only reconnect it WHEN THE CAUSE OF OVERLOAD HAS BEEN
ESTABLISHED. This could be caused by a fault with the cables, the equipment
powered by the battery belt, the connectors, or a fault internal to the battery
belt.

2.7

The leather is wax treated during manufacture to resist water absorption in
normal use. Occasional cleaning and polishing with colourless wax polish will
maintain the suppleness of the leather, water resistance and appearance.

2.8

Nickel-Cadmium cells must never be replaced indiscriminately. All cells
used by PAG Limited are carefully graded and matched because battery
performance is only as good as the worst cell, and fitting unmatched
cells will quickly result in battery failure.

2.9

PAG Ltd. maintains a comprehensive Service Department for the repair and
service of all Nickel-Cadmium batteries and charging equipment. The depart-
ment is based at the London factory and is therefore able to call upon full
manufacturing and test facilities. Should your Pagbelt require servicing we
recommend that you contact your PAG Dealer or the PAG Service Department
to maintain the quality standard for which you originally chose your Pagbelt.

INSTRUCTIONS FOR USE

SECTION 3

Содержание pagbelt

Страница 1: ...Instruction Manual Pagbelt Ni Cd Battery Belt ...

Страница 2: ...n output sockets 4 Quick release buckle 5 Shoulder harness attaching rings 6 Charging mains LED IC2 version only 7 Waist strap 8 Over discharge and thermal protection reset button 9 Mains input socket IC2 versions only 3 5 5 7 5 1 3 8 4 9 4 6 2 Pagbelt IC2 S2 General Arrangement ...

Страница 3: ...CONTENTS SECTION PAGE 1 SPECIFICATION 2 2 CARE AND MAINTENANCE 4 3 INSTRUCTIONS FOR USE 5 4 SAFETY 7 5 WARRANTY 9 Pagbelt Ni Cd Battery Belt Instruction Manual ...

Страница 4: ...99 24 0V S2 9190 39195 IC2 9290 39295 30 0V S2 9191 89196 IC2 9291 89296 Supplied with shoulder harness 1 2 Cells Premium grade Nickel Cadmium sealed rechargeable cylindrical cells 1 3 Voltages Nominal voltage 1 2V per cell 1 4 Capacity Capacities shown are as measured at the five hour rate 1 5 Over Discharge Protection ODP All models incorporate the PAG ODP circuit which will trip at the followin...

Страница 5: ...ection Pin 3 No connection Pin 4 Positive 1 9 Pagbelt Construction Battery pouches deep moulded from top quality full chrome hide Connection to the Pagbelt is made via a housing injection moulded from glass reinforced nylon 1 10 Waist Strap Waist strap incorporates quick release buckle and is secured to the belt carcass 1 11 Shoulder Harness Certain Pagbelts are provided with a shoulder harness se...

Страница 6: ...age temperatures below 30 C are also to be avoided since the electrolyte may freeze result ing in permanent cell damage After prolonged storage do not fast charge the battery immediately The cells should first be reformed and balanced by giving the battery a slow C 10 charge for 24 hours When the battery is subsequently put into service 2 or 3 cycles of charge and discharge may be needed to return...

Страница 7: ...ip causing the output to become open circuit In this event disconnect any equipment from the output and only reconnect it WHEN THE CAUSE OF OVERLOAD HAS BEEN ESTABLISHED This could be caused by a fault with the cables the equipment powered by the battery belt the connectors or a fault internal to the battery belt 2 7 The leather is wax treated during manufacture to resist water absorption in norma...

Страница 8: ... suitable for use with Nickel Cadmium batteries and may damage them irreparably When a battery belt has been discharged at high current rates it will become warm and it is advisable to let it cool before recharging it The recommended charging temperature range is 0 C to 40 C IC2 Pagbelts incorporate an internal overnight charger see Section 3 3 below for operating instructions All Pagbelts may be ...

Страница 9: ...g the charging process and ensure that the ODP cut out is reset by pressing the reset button Connect the charging lead from the charger to an output connector XLR 4 on the Pagbelt using an adaptor lead if necessary PAG microcomputer controlled fast chargers will automatically terminate the charging process when the battery is fully charged For typical charging times and full operating instructions...

Страница 10: ... result in damage to cells and short circuit internal to the battery Arcing excessive heat and the liberation of combustible gas could result with the potential for personal injury or ignition of adjacent flammable materials 4 5 DISPOSAL DO NOT MUTILATE BATTERIES corrosive electrolyte will be released see 4 3 DO NOT INCINERATE danger of explosion and release of toxic fumes DO NOT DISPOSE OF BATTER...

Страница 11: ...hin the period of the warranty provided the warrantor s examination discloses to its satisfaction the product was defective The warrantor may at its option replace the product in lieu of repair With regard to any equipment returned within this period said repairs or replacements will be made without charge If the failure has been caused by misuse neglect accident or abnormal conditions of operatio...

Страница 12: ...U4919 ISS C OCT 03 T 44 0 20 8543 3131 F 44 0 20 8540 4116 E sales paguk com www paguk com PAG Ltd 565 Kingston Road Raynes Park London SW20 8SA ...

Отзывы: