background image

OUTPUT VOLTAGE 
METER

INPUT VOLTAGE 
METER

DELAYING INDICATOR

WORKING INDICATOR

UNUSUAL INDICATOR

DELAY / UNDELAY 
SELECTOR

POWER SWITCH

INPUT VOLTAGE 
TURBO SELECTOR

OUTPUT VOLTAGE 
METER

INPUT VOLTAGE 
METER

DELAYING INDICATOR

WORKING INDICATOR

UNUSUAL INDICATOR

DELAY / UNDELAY 
SELECTOR

POWER SWITCH

INPUT VOLTAGE 
TURBO SELECTOR

Front Panel: 1000VA-2000VA

Rear Panel: 1000VA-2000VA

FIG 2

SWR-1000VA

Input Voltage

Microprocessor Control(CPU)

High & Low Voltage Protection 

Output Voltage

AUTOMATIC VOLTAGE REGULATOR

Fuse

Input

Output

Front Panel: 3000VA-5000VA

Rear Panel: 3000VA-5000VA

FIG 3

Microprocessor Control(CPU)

High & Low Voltage Protection 

SWR-5000VA

AUTOMATIC VOLTAGE REGULATOR

2

Input

GND

Output

Output

Содержание SWR-3000VA

Страница 1: ...VOLTAGE REGULATOR HIGH LOW VOLTAGE PROTECTION Instruction Manual Please read user manual carefully before use S WR 1 0 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltage Protection Outp...

Страница 2: ...1 Front Panel 300 500VA Rear Panel 300VA 500VA S WR 5 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltage Protection Output Voltage AUTOMATICVOLTAGEREGULATOR Fuse Input Output 1 OUTPUT V...

Страница 3: ...ATOR DELAY UNDELAY SELECTOR POWER SWITCH INPUT VOLTAGE TURBO SELECTOR Front Panel 1000VA 2000VA Rear Panel 1000VA 2000VA FIG 2 S WR 1 0 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltag...

Страница 4: ...TAGE METER INPUT VOLTAGE METER DELAYING INDICATOR WORKING INDICATOR UNUSUAL INDICATOR DELAY UNDELAY SELECTOR POWER SWITCH INPUT VOLTAGE TURBO SELECTOR Microprocessor Control CPU High Low Voltage Prote...

Страница 5: ...ve only after users notify manufacturer in advance WHEN OUTPUT VOLTAGE OF AVR IS HIGHER THAN SET VALUE THE SYSTEM ENTER INTO HIGH LOW VOLTAGE PROTECTION UNUSUAL RED LED FLASHES EVERY ONE SECOND AND OU...

Страница 6: ...ltage and power of the appliance are accord with the labeled power and specification of the unit to avoid any damage Please connect the appliance before turning on the unit Switch on appliance after y...

Страница 7: ...ition delay time is 120 seconds When TURBO ON input voltage range is the rated input voltage labeled on the unit When TURBO OFF input voltage range is to be narrowed down 20V NOTE This turbo function...

Страница 8: ...ower or higher than labeled voltage AVR will turn into self protection state automatically the UNUSUAL RED indicator flashes every one second and output voltage will be cut off 7 THERMAL PROTECTION 8...

Страница 9: ...e automatic voltage regulator and also to the earth terminal of the AC output socket The use of this terminal will depend on your particular installation In any installation heavy duty green insulated...

Страница 10: ...neutral line is bonded to earth and there is normally no voltage between them In a stationary land based installation the earth terminal should be connected to a metal earthing stake driven into the g...

Страница 11: ...nect all units C check the connected devices D use the unit again unless the problems concerning the connected devices have been solved When in use for a prolonged period of time the AC output may sud...

Страница 12: ...f Protector For 12 EXPERT OF PROTECTOR FOR Make sure that the to tal laden power does not exceed the listed maximum output power of the regulator Be sure to connect the ground point to the ground for...

Страница 13: ...10 Circuit Protection Circuit Protection 255V 250V AC T5 0A 5x20mm 2 9Kg 1000VA 1500VA 2000VA 250V AC T8 0A 250V AC T10A 250V AC T15A 4 7Kg 5 5Kg 6 7Kg 220V 230V 240V 110V 115V Thermal Protection O 1...

Страница 14: ...A 220V 230V 240V 110V 115V SWR 3000VA SWR 5000VA SWR 8KVA SWR 10KVA 39x21 5x26cm 47x28x36 cm Yes Auto operation fan temperature or load 6 secs 120 secs Input Fuse Fuse Size Delay Time Dimension L x W...

Страница 15: ...ut power of the regulator For color TV calculate it twice as its listed capacity Make sure that the regulator is of the same output voltage and frequency as the appliance s it connected Make sure that...