packardonline.com | 800.334.1769
14
Specifications
Voltage Ratings
• 115VAC (white voltage plug) allowable range 90-132VAC
• 230VAC (yellow voltage plug) allowable range 180-264VAC
Horsepower Ratings
1/3, 1/2, 3/4 & 1
FLA Ratings
• 1/3 Hp = 5.0/3.0
• 1/2 Hp = 6.7/4.0
• 3/4 Hp = 8.2/4.9
• 1 Hp = 11.0/6.7
RPM Rating
1075
Speeds
(see chart below for estimated RPM values)
• 4 speeds (LOW, MED-LOW, MED-HI & HI)
Rotation
CW or CCW (automatically configured)
Bearing
Ball
Ambient Rating
40°C
Enclosure
Open Air Over (OAO)
Frame size and dimensions
NEMA 48 Frame (5.6” diameter) see diagram
below for DIM A & B
• 1/3 Hp (DIM A = 11.26), (DIM B = 6.34)
• 1/2 Hp (DIM A = 11.26”), (DIM B = 6.34”)
• 3/4 Hp (DIM A = 12.76”, (DIM B = 7.84”)
• 1 Hp (DIM A = 12.76”), (DIM B = 7.84”)
Shaft
.5” x 5” (4.5” single flat)
Mounting
Belly band (not supplied)
Harness
Lead length 48”
UL Recognized Component
4kV surge protection
SPEED (RPM) RATINGS.
NOTE: ACTUAL RPM WILL
VARY DEPENDING ON LOAD.
HI = 1075 RPM
MED-HI = 1000 RPM
MED LOW = 925 RPM
LOW = 850 RPM