OPERATING PROCEDURES

OPERATION (continued)

10. As dirty solution is recovered, some foaming may be noted.  Excessive foaming can be counteracted with liquid

       defoamer applied according to the chemical manufacturers directions.  DO NOT ALLOW FOAM TO RISE INTO OR NEAR

       THE DOME;  THIS WILL HARM THE VACUUM MOTOR.  Use defoamer or empty and flush the recovery tank.   

11. To empty the recovery tank, remove the dome assembly and lift the tank out.  Dispose of the recovered water properly.  

12. If streaking occurs after a period of operating time, this means the solution (fresh water) tank is near empty.  Streaking

       is eliminated by adding more water and chemical solution to the tank.  EMPTY THE RECOVERY TANK EVERY TIME YOU 

       FILL THE SOLUTION TANK.  

13. To empty the solution tank, connect the power fill adaptor to the vacuum inlet on the front of the dome.  Turn the  

       vacuum switch on.   

  

OPERATING WITH ACCESSORY TOOLS

  

1.   To use an accessory tool, disconnect the supply hose at the rear of the machine and connect the accessory tool hose.  

2.   Next, disconnect the machine’s vacuum hose from the front of th edome assembly and connect the accessory tool

      vacuum hose to the dome.  

3.   Turn the vacuum and accessory pump switches on.  Solution will be dispensed while the accessory tool trigger is  

      depressed.  

WATCH THE DOME TO MAKE SURE THE RECOVERY TANK DOES NOT OVERFLOW.  

Note:  The pump motor is equipped with an automatic thermal protection device.  If the motor overheats for any reason, 

the thermal protector will activate and automatically turn the motor off.  If this occurs the operator should turn the manual 

pump switch to the off position and allow approximately fifteen minutes for the motor to cool.  When the motor has cooled 

to a safe operating termperature, the thermal protector will automatically close and allow power to be supplied to the 

motor via the manual pump switch.  The operator will be able to resume normal operation.  If the pump motor shuts down 

repeatedly, it should be checked at an Authorized Service Center.  

SERVICING  

This self-contained extractor is designed and manufactured to provide years of trouble free service with a minimum of  

maintenance and service.  The following recommendations are intended to assist the operator and Service Technician in 

performing routine maintenance.

WARNING:  Always unplug your machine before performing any service.  Severe personal injury could result if the 

electrical power is not disconnected.  

After each use:  

1.    Clean the dome top, intake filter screen, gasket and recovery tank with fresh, clean water.  Do not reinstall the dome 

       until the next use, this will allow the recovery tank to dry out.  

2.   Flush the solution tank and inlet screen with clean water.  Vacuum all water out using the Power Fill adapter.  

3.  Remove any debris on the scrub brush, vacuum head and around the spray jets.  

4.   Make sure the brush assembly lift lever is locked in the rasied position.  

5.  Store your machine in a dry, protected area.  

Do not expose this machine to rain, standing water or freezing 

      temperatures.

Periodically:  

After continuous or repeated use the jets and check valves will need cleaning.  Unplug the cord and empty the recovery 

and solution tanks.  Tilt the machine backwared.  Remove the jet caps, jets and check valves shown in the brush assembly 

illustration and soak in white vinegar until visible deposits are dissolved, then scrub with a soft bristle brush.  

Note:  Jets and 

check valves should be replaced once a year, 

because they tend to erode under extended use.  This may cause overuse of 

solution and streaking.     

  

An Authorized Service Center should perform the following procedures:  

The cogged belt drive system rarely requires tightening.  If the belt becomes loose from wear, it is time to replace it.  To do 

so, remove acorn nut and thru-bolt from brush chassis lift handle.  Gently tilt machine backwards.  While holding the base of 

the brush housing with one hand, release the lift handle from the up/locked position.  The brush housing privots on a hinge 

thta doesn’t need to be removed.  Loosen the two motor bracket mounting bolts with a 7/16” wrench.  DO NOT REMOVE 

THE BOLTS UNLESS YOU ARE REPLACING THE MOTOR.  Slide the motor away from the brush to tighten the belt or toward 

the brush to remove.  If you are replacing the belt it will be necessary to remove the brush assembly to install a new one.

Содержание SCE-4

Страница 1: ...kegon MI 49442 6252 Carefully inspect all components to ensure that there is no concealed freight damage If such damage is discovered file a CONCEALED DAMAGE REPORT immediately with the delivering car...

Страница 2: ...the plug illustrated in figure A A temporary adapter that looks like the adapter illustrated in figures B and C may be used to connect this plug to a 2 pole receptacle as shown in figure B if a prope...

Страница 3: ...e a door on cord or pull cord around sharp edges or corners Keep cord away from heated surfaces 8 Do not use with damaged cord or plug If the machine is not working as it should has been dropped damag...

Страница 4: ...er operation of your machine Failure to follow these recommended procedures can reduce the machine s performance and may result in damage to the machine 1 Vacuum the area to be cleaned Your machine wi...

Страница 5: ...manufactured to provide years of trouble free service with a minimum of maintenance and service The following recommendations are intended to assist the operator and Service Technician in performing...

Страница 6: ...OVE THE BOLTS UNLESS YOU ARE REPLACING THE MOTOR 5 Slide the motor away from the brush to tighten the belt or toward the brush to remove If you are replacing the belt it will be necessary to remove th...

Страница 7: ...SCE 4 SELF CONTAINED EXTRACTOR 7...

Страница 8: ...SCE 4 SELF CONTAINED EXTRACTOR DRAWING 1 8...

Страница 9: ...1 15 205070 Knob Brush Lift 1 47 3704 Switch Momentary 1 16 962086 Bolt 1 4 20 x 1 1 4 Carriage 1 48 206651 Plate Momentary Switch 1 17 203970 Bracket Handle Lift 1 49 911089 Switch Rocker 20Amp 2 18...

Страница 10: ...SCE 4 SELF CONTAINED EXTRACTOR DRAWING 2 10 48...

Страница 11: ...ass 2 13 W169D Screw 1 4 20 x 1 2 HH CS SS 6 47 S973P Cap Jet 2 14 204181 Hose Bulkhead to Pump 1 48 200970 Brush Assembly Complete 1 15 240202 Adaptor Hose to Dome 1 49 962062 Screw 8 x 1 HILO PHP TC...

Страница 12: ...s subject to incoming inspection of those items To secure repair under this warranty the following procedure should be taken The inoperative machine or warranted parts must be delivered to the authori...

Отзывы: