5HPDUN
A. Functions:
B. Operating lnstructions:
1. Pour distilled water or decalcified water into provided jar.
2. Pour distilled water or decalcified water from the jar into the
hidden water storage unit of the range hood through the water
inlet as shown in the picture. First time use the hood, please
pour the volume of two provided jars.
3. Press the steam clean button to start the motors and the distilled
water or decalcified water will be discharged automatically
and cleans the inside of the range hood.
4. The oil retainer shall be taken out to remove the dirty oil once
the dirty oil and residue reaches the window of oil retainer
to prevent spillage.
C. Precautions:
1. Use distilled water or decalcified water for steam clean.
2. Use the provided jar to pour distilled water or decalcified water.
3. Consumers are advised to clean the range hood twice a week. It may be cleaned
less frequently according to individual needs.
4. When filling the range hood with the distilled water or decalcified water,use only
the provided jar the provided jar with the range hood and take precautions not to
overfill the cleaner storage unit.
5. Check and empty the oil retainer after the cleaning process to prevent oil spillage.
Do not allow dirty oil and residue to exceed the height of window.
6. Do not put any other substances into the water storage unit as this will cause
blockage of its steam nozzle.
7. Suggest to take out the oil retainer to remove the dirty oil after every steam clean.
8. When using the steam clean function for the first time you might see some vapors
or smell smoke from the hood, this is the anti-rust oil from the heating block evaporating
after heating and should not be cause for alarm.
1. The range hood should be cleaned by using distilled water or decalcified water only.
The cleaning process works by centrifuga force and cleaning power generated by
revolving motors at high speed, It will keep the inside of the blower housing clean
and prolong the lifespan of the range hood.
2. Steam clean function will auto-lock if the function senses an error, the indication light
of user interface will blink indicating an error. Please contact supplier for details or
repair.
Water inlet
Water
storage unit
JAR
decalcified
distilled water
.